Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4. Check backplane cable connection.
5.
Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
•
806f050d-041dffff : Array [ComputerSystemElementName] is in critical condition. (Drive 29)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d041dffff or 0x806f050d041dffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
728
Lenovo System x3650 M5 Installation and Service Guide
Содержание x3650 M5
Страница 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Страница 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Страница 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1329: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1317 ...
Страница 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1339: ......
Страница 1340: ......