4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
•
215-902-000 : Optical Drive Test Failed
Optical Drive Test Failed. Read miscompare.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized.
Rerun the test.
2. Check the drive cabling for loose or broken connections at both ends or damage to the cable.
Replace the cable if damage is present.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
•
215-903-000 : Optical Drive Test Aborted
Optical Drive Test Aborted. Could not access the device.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
1286
Lenovo System x3650 M5 Installation and Service Guide
Содержание x3650 M5
Страница 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Страница 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Страница 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1329: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1317 ...
Страница 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1339: ......
Страница 1340: ......