User Response
1. Make sure that one or more DIMMs are installed in the server, and resolve any other currently
existing memory errors.
2. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that
all DIMM connectors are enabled using the Setup utility or the ToolsCenter Suite CLI.
3. Re-Install all DIMMs verifying the correct population sequence, according to the service
information for this product.
4.
Replace DIMMs.
5. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt,
press F3 to recover the firmware. c. Update the server firmware on the primary page. Important:
Some cluster solutions require specific code levels or coordinated code updates. If the device is
part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
6. If the problem remains, (trained technician only) replace the system board.
Firmware Error : Sys Boot Status : X8 PCI 1 Firm : X8 PCI 2 Firm : X8 PCI 6 Firm : X8 PCI 7 Firm :
•
806f000f-220103ff : The System [ComputerSystemElementName] encountered firmware error -
unrecoverable boot device failure. (ABR Status)
This message is for the use case when an implementation has detected that System Firmware Error
Unrecoverable boot device failure has occurred.
May also be shown as 806f000f220103ff or 0x806f000f220103ff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0770
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status : X8
PCI 1 Firm : X8 PCI 2 Firm : X8 PCI 6 Firm : X8 PCI 7 Firm :
•
806f000f-220104ff : The System [ComputerSystemElementName]has encountered a motherboard
failure. (ABR Status)
548
Lenovo System x3650 M5 Installation and Service Guide
Содержание x3650 M5
Страница 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Страница 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Страница 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1329: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1317 ...
Страница 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1339: ......
Страница 1340: ......