contaminated, you must wipe off the contaminated thermal material on the microprocessor or heat
sink with the alcohol wipes and reapply clean thermal grease to the heat sink.
a.
Open the heat sink retention module release lever to the fully open position.
Heat sink
release lever
Figure 241. Heat sink retention module release lever
b.
Lift the heat sink out of the server. After removal, place the heat sink (with the thermal grease
side up) on a clean, flat surface.
Heat sink
release lever
Lock tab
Heat sink
Figure 242. Heat sink removal
Step 8.
Open the microprocessor socket release levers and retainer.
Installing, removing, and replacing components
277