The following illustration shows the status of the jumpers on the system board of your server.
Figure 32. System board jumpers
Table 2. System board jumpers
1
Clear password jumper
2
BIOS default settings jumper
3
BIOS recovery jumper
Attention:
To set the jumpers, remove the server cover and the cooling shroud to access the system board.
Do not open your server or attempt any repair before reading and understanding “Read this first: safety
information” on page iii and “Guidelines” on page 69.
1
Clear password jumper
Use the jumper to erase forgotten passwords, such as an administrator password and a user password.
To clear passwords, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server. If
the server is in tower form factor, lay the server on its side for easier operation.
3. Remove the server cover. See “Removing the server cover” on page 72.
52
ThinkServer TD350 User Guide and Hardware Maintenance Manual
Содержание ThinkServer TD350
Страница 14: ...xii ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 206: ...192 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 213: ...China RoHS Appendix A Notices 199 ...
Страница 224: ...210 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 225: ......
Страница 226: ......