1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server. If
the server is in tower form factor, lay the server on its side for easier operation.
3. Remove the server cover. See “Removing the server cover” on page 72.
4. Locate the backplanes. See “Hot-swap-drive backplane” on page 39.
5. Remove the AnyRAID adapter. See “Replacing the AnyRAID adapter” on page 159.
6. Remove all the installed hot-swap storage drives and dummy trays (if any) from the storage-drive bays.
See “Installing or replacing a hot-swap internal storage drive” on page 127.
7. Record the cable connections on the backplane, and then disconnect all the cables from the backplane.
8. Depending on the server model, do one of the following:
• For the server models with 3.5-inch-drive backplane, press the two release tabs
1
and gently lift the
3.5-inch-drive backplane a little bit upward so that it is released from the hooks on the chassis. Then,
carefully remove the 3.5-inch-drive backplane out of the chassis.
Figure 133. Removing the 3.5-inch-drive backplane
164
ThinkServer TD350 User Guide and Hardware Maintenance Manual
Содержание ThinkServer TD350
Страница 14: ...xii ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 206: ...192 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 213: ...China RoHS Appendix A Notices 199 ...
Страница 224: ...210 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 225: ......
Страница 226: ......