6. Remove any installed PCIe card (such as the Ethernet card) that impedes your access to the coin-cell
battery. See “Removing a PCIe card” on page 93.
7. Remove the old coin-cell battery.
Figure 140. Removing the coin-cell battery
8. Install a new coin-cell battery.
Figure 141. Installing the coin-cell battery
9. Reinstall the PCIe card (such as the Ethernet card) that has been removed. See “Installing a PCIe
10. Dispose of the old coin-cell battery as required by local ordinances or regulations.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to “Completing the parts replacement” on page 180. After you replace
the coin-cell battery, you must reset passwords, reset system date and time, and reconfigure the server.
See Chapter 5 “Configuring the server” on page 57.
Connecting an external tape drive
Attention:
Do not open your server or attempt any repair before reading and understanding “Read this first: safety
information” on page iii and “Guidelines” on page 69.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• Depending on the model, your tape drive might look slightly different from the illustrations in this topic.
• Use any documentation that comes with the tape drive and follow those instructions in addition to
the instructions in this topic.
To connect an external tape drive, do the following:
173
Содержание ThinkServer TD350
Страница 14: ...xii ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 206: ...192 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 213: ...China RoHS Appendix A Notices 199 ...
Страница 224: ...210 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 225: ......
Страница 226: ......