806f050d-0406ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 6)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0406ffff or 0x806f050d0406ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4. Check backplane cable connection.
5.
Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
•
806f050d-0407ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 7)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0407ffff or 0x806f050d0407ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
Appendix A. Integrated Management Module II (IMM2) error messages
431
Содержание System x3250 M5
Страница 1: ...Lenovo System x3250 M5 Installation and Service Guide Machine Type Type 5458 ...
Страница 6: ...iv Lenovo System x3250 M5Installation and Service Guide ...
Страница 36: ...22 Lenovo System x3250 M5Installation and Service Guide ...
Страница 98: ...84 Lenovo System x3250 M5Installation and Service Guide ...
Страница 122: ...108 Lenovo System x3250 M5Installation and Service Guide ...
Страница 162: ...Figure 84 Server components 148 Lenovo System x3250 M5Installation and Service Guide ...
Страница 546: ...532 Lenovo System x3250 M5Installation and Service Guide ...
Страница 722: ...708 Lenovo System x3250 M5Installation and Service Guide ...
Страница 738: ...724 Lenovo System x3250 M5Installation and Service Guide ...
Страница 739: ......
Страница 740: ......