Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0495
User Response
No action; information only.
•
81010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical)
has deasserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has deasserted.
May also be shown as 810109020701ffff or 0x810109020701ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix:
PLAT
ID:
0495
User Response
If the specified sensor is one of the following, SysBrd 3.3V, SysBrd 5V or SysBrd 12V: No action;
information only.
•
81010b01-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper
non-recoverable) has deasserted. (PCI Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has deasserted.
May also be shown as 81010b010701ffff or 0x81010b010701ffff
Appendix A. Integrated Management Module II (IMM2) error messages
463
Содержание System x3250 M5
Страница 1: ...Lenovo System x3250 M5 Installation and Service Guide Machine Type Type 5458 ...
Страница 6: ...iv Lenovo System x3250 M5Installation and Service Guide ...
Страница 36: ...22 Lenovo System x3250 M5Installation and Service Guide ...
Страница 98: ...84 Lenovo System x3250 M5Installation and Service Guide ...
Страница 122: ...108 Lenovo System x3250 M5Installation and Service Guide ...
Страница 162: ...Figure 84 Server components 148 Lenovo System x3250 M5Installation and Service Guide ...
Страница 546: ...532 Lenovo System x3250 M5Installation and Service Guide ...
Страница 722: ...708 Lenovo System x3250 M5Installation and Service Guide ...
Страница 738: ...724 Lenovo System x3250 M5Installation and Service Guide ...
Страница 739: ......
Страница 740: ......