Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix:
PLAT
ID:
0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10.
If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server
to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor. One of the DIMMs :
•
806f010d-0400ffff : The Drive [StorageVolumeElementName] has been disabled due to a detected
fault. (Drive 0)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d0400ffff or 0x806f010d0400ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
400
Lenovo System x3250 M5Installation and Service Guide
Содержание System x3250 M5
Страница 1: ...Lenovo System x3250 M5 Installation and Service Guide Machine Type Type 5458 ...
Страница 6: ...iv Lenovo System x3250 M5Installation and Service Guide ...
Страница 36: ...22 Lenovo System x3250 M5Installation and Service Guide ...
Страница 98: ...84 Lenovo System x3250 M5Installation and Service Guide ...
Страница 122: ...108 Lenovo System x3250 M5Installation and Service Guide ...
Страница 162: ...Figure 84 Server components 148 Lenovo System x3250 M5Installation and Service Guide ...
Страница 546: ...532 Lenovo System x3250 M5Installation and Service Guide ...
Страница 722: ...708 Lenovo System x3250 M5Installation and Service Guide ...
Страница 738: ...724 Lenovo System x3250 M5Installation and Service Guide ...
Страница 739: ......
Страница 740: ......