If the specified sensor is one of the following, PS1 12V OC Fault, PS1 12V OV Fault, PS1 12V UV
Fault or PS1 12Vaux Fault: No action; information only.
•
810b0108-1301ffff : Redundancy Lost for [RedundancySetElementName] has deasserted. (Power
Unit)
This message is for the use case when Redundacy Lost has deasserted.
May also be shown as 810b01081301ffff or 0x810b01081301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix:
PLAT
ID:
0803
User Response
No action; information only.
•
816f0007-0301ffff : [ProcessorElementName] has Recovered from IERR. (CPU 1)
This message is for the use case when an implementation has detected a Processor Recovered - IERR
Condition.
May also be shown as 816f00070301ffff or 0x816f00070301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix:
PLAT
ID:
0043
User Response
Appendix A. Integrated Management Module II (IMM2) error messages
475
Содержание System x3250 M5
Страница 1: ...Lenovo System x3250 M5 Installation and Service Guide Machine Type Type 5458 ...
Страница 6: ...iv Lenovo System x3250 M5Installation and Service Guide ...
Страница 36: ...22 Lenovo System x3250 M5Installation and Service Guide ...
Страница 98: ...84 Lenovo System x3250 M5Installation and Service Guide ...
Страница 122: ...108 Lenovo System x3250 M5Installation and Service Guide ...
Страница 162: ...Figure 84 Server components 148 Lenovo System x3250 M5Installation and Service Guide ...
Страница 546: ...532 Lenovo System x3250 M5Installation and Service Guide ...
Страница 722: ...708 Lenovo System x3250 M5Installation and Service Guide ...
Страница 738: ...724 Lenovo System x3250 M5Installation and Service Guide ...
Страница 739: ......
Страница 740: ......