Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix:
PLAT
ID:
0086
User Response
1.
Reseat power supply n.
2. If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
3. If both the power-on LED and the power-supply error LED are not lit, see Power problems for
more information. (n = power supply number)
•
806f0108-0a02ffff : [PowerSupplyElementName] has Failed. (Power Supply 2)
This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a02ffff or 0x806f01080a02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix:
PLAT
ID:
0086
User Response
1.
Reseat power supply n.
2. If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
Appendix A. Integrated Management Module II (IMM2) error messages
395
Содержание System x3250 M5
Страница 1: ...Lenovo System x3250 M5 Installation and Service Guide Machine Type Type 5458 ...
Страница 6: ...iv Lenovo System x3250 M5Installation and Service Guide ...
Страница 36: ...22 Lenovo System x3250 M5Installation and Service Guide ...
Страница 98: ...84 Lenovo System x3250 M5Installation and Service Guide ...
Страница 122: ...108 Lenovo System x3250 M5Installation and Service Guide ...
Страница 162: ...Figure 84 Server components 148 Lenovo System x3250 M5Installation and Service Guide ...
Страница 546: ...532 Lenovo System x3250 M5Installation and Service Guide ...
Страница 722: ...708 Lenovo System x3250 M5Installation and Service Guide ...
Страница 738: ...724 Lenovo System x3250 M5Installation and Service Guide ...
Страница 739: ......
Страница 740: ......