If you are replacing a server component in the server, you need to slide the server out from the rack
enclosure, turn off the server and peripheral devices, and disconnect the power cords and all external cables.
To install a hypervisor flash device, complete the following steps.
Step 1.
Remove the cover (see “Removing the cover” on page 33).
Step 2.
Remove the PCI riser-card assembly (see “Removing the PCI riser-card assembly” on page 163).
Step 3.
Locate the USB embedded hypervisor flash device connector on the system board.
Figure 64. Location of the USB embedded hypervisor flash device connector
Step 4.
Align the USB flash device with the connector on the system board and push it into the connector
until it is firmly seated.
Step 5.
Slide the lockbar on the flash device connector to the locked position until it is firmly seated.
71