Maintenance Guide 
 

NEC Express Server 
Express5800 Series 
 

80.102.01-104.01 

September 2014, Rev.1.20 

© NEC Corporation 2014 

 
 

Chapter 1  Maintenance 

 

Chapter 2  Convenient Features 

 

Chapter 3  Appendix 
 

 

Express5800/

 

A1040b, A2040b,   

A2020b, A2010b 

 
 

Содержание NEC Express5800 Series

Страница 1: ...ide NEC Express Server Express5800 Series 80 102 01 104 01 September 2014 Rev 1 20 NEC Corporation 2014 Chapter 1 Maintenance Chapter 2 Convenient Features Chapter 3 Appendix Express5800 A1040b A2040b...

Страница 2: ...tallation of Windows and drivers and important information for installation Chapter 2 Installing the Bundled Software Installation of bundled software such as NEC ESMPRO and Universal RAID Utility PDF...

Страница 3: ...ecking and Applying Updates 24 2 2 Checking Alerts 24 2 3 Checking SYSTEM STATUS LED 25 2 4 Backup 25 2 5 Cleaning 25 2 5 1 Cleaning the server 27 2 5 2 Cleaning the tape drive 27 2 5 3 Cleaning the k...

Страница 4: ...ostics 53 8 1 Test Items 53 8 2 Flow of System Diagnostics 54 8 2 1 Starting System Diagnostics 54 8 2 2 Confirming device configuration information 55 8 2 3 Executing test 56 8 2 4 Saving Logs 58 8 2...

Страница 5: ...6 9 Express Report Service Express Report Service HTTPS 107 10 Express Report Service MG 108 Chapter 33 Appendix 109 1 POST Error Message 110 2 List of Windows Event Logs 115 3 Accessing Data for Elec...

Страница 6: ...s that must be confirmed when handling the hardware or operating software Tips Indicates information that is helpful to keep in mind when using this server Optical disk drives This server has one of t...

Страница 7: ...2008 R2 Datacenter SP1 or later 1 For Windows Server 2012 R2 refer to Support Kit provided through the following web site http www 58support nec co jp global download w2012r2 index html Abbreviations...

Страница 8: ...scribed in this document refer to the following Web browser to use remote management feature via HTTP HTTPS protocol using EXPRESSSCOPE Engine SP3 BMC and contents used for remote management control E...

Страница 9: ...Systems Incorporated DLT and DLTape are trademarks of Quantum Corporation of the United States LTO is a trademark of International Business MachinesCorporation Hewlett Packard Company and Seagate Tec...

Страница 10: ...legislation or agreements you may have The mark on the electrical and electronic products only applies to the current European Union Member States Outside the European Union If you wish to dispose of...

Страница 11: ...B PBDE HDD DVD SJ T11363 2006 SJ T11363 2006 Vietnam RoHS information relevant for Vietnam market Complying with CIRCULAR No 30 2011 TT BCT Hanoi August 10 2011 Temporary regulations on content limit...

Страница 12: ...azardous substance with the exemption of the applications listed in the Annex 2 of TR on RoHS 1 Lead Pb not over 0 1wt or 1000wt ppm 2 Cadmium Cd not over 0 01wt or 100wt ppm 3 Mercury Hg not over 0 1...

Страница 13: ...no liability arising from the use of this product nor any liability for incidental or consequential damages arising from the use of this User s Guide regardless of Item 4 6 The sample values used in...

Страница 14: ...ion Describes how to collect information about the location where a failure occurred and its cause when the server malfunctions Refer to this section in case of a failure 5 Troubleshooting Describes h...

Страница 15: ...umes no liability for data leakage should the product be transferred to a third party without erasing the data Data seems to be erased when you empty Recycle Bin of Windows or execute the format comma...

Страница 16: ...d disk drives backup data cartridges or any other media such as CD R CD RW so that the data cannot be restored by a third party Some components including cooling fans batteries and the optical disk dr...

Страница 17: ...emble repair or alter the server Do not remove the lithium battery NiMH or Li ion battery Disconnect the power plug before installing or removing the server CAUTION Be sure to observe the following pr...

Страница 18: ...um NiMH ou les batteries Li ion D branchez la fiche d alimentation avant d installer ou de retirer le serveur ATTENTION Conformez vous aux instructions suivantes pour utiliser le serveur en toute s cu...

Страница 19: ...H o a ioni di litio Scollegare la presa dell alimentazione prima di installare o rimuovere il server ATTENZIONE Accertarsi di osservare le seguenti precauzioni per utilizzare il server in modo sicuro...

Страница 20: ...ium Batterie NiMH oder Li Ionen Batterie Ziehen Sie den Stromstecker vom Netz bevor Sie den Server installieren oder entfernen ACHTUNG Achten Sie darauf die folgenden Vorsichtsma nahmen zu beachten um...

Страница 21: ...litio NiMH ni la bater a de i n de litio Desconecte el enchufe antes de instalar o retirar el servidor CUIDADO Aseg rese de respetar las precauciones que figuran a continuaci n para utilizar el servid...

Страница 22: ...ve If the server has hard disk drives move the server while being careful not to damage the drive When storing the server monitor the environmental conditions of the storage area temperature 10 C to 5...

Страница 23: ...erver and internal optional devices are suddenly moved from a cold place to a warm place condensation will occur and cause malfunctions and failures when these are used in such state Wait for a suffic...

Страница 24: ...58support nec co jp global download index html Support Downloads NEC also provides ExpressUpdate that supports the detection download and application of the updates that must be applied to BIOS and F...

Страница 25: ...stem back to the state before replacement If RAID System is built on your system back up RAID Configuration Data We also recommend that you back up it after a rebuilt required due to HDD failure For i...

Страница 26: ...ese Vorsichtsma nahmen nicht beachtet kann es zum Tod oder zu ernsthaften Verletzungen kommen Einzelheiten finden Sie auf Sicherheitsma nahmen in Vorsichtsma nahmen beim Gebrauch im Bedienungsanleitun...

Страница 27: ...ared in step 4 6 Soak a soft cloth in water squeeze it firmly and wipe the server with it once again 7 Wipe the server with a dry cloth 8 Wipe off dust from the inlet port of fan located at front of t...

Страница 28: ...nt Do not touch the signal side of the CD DVD media with your hand 4 Wipe the tray with a dry soft cloth Important Do not wipe the lens of the optical disk drive Doing so may damage the lens and may c...

Страница 29: ...and cables to other products are properly connected 2 Refer to Chapter 1 5 Troubleshooting If you find a symptom similar to your problem take the action as instructed 3 Confirm that the required softw...

Страница 30: ...shortage Ignore this message and proceed with starting the system Resetting the system may result in an inability to properly dump the data 4 1 Collecting Event Logs for Windows To collect various eve...

Страница 31: ...1 Maintenance 2 Click Control Panel from Settings 3 Click System and Security of Control Panel 4 Click Administrative Tools and then click View event logs of System and Security Express5800 A1040b A2...

Страница 32: ...t to save in Save as type and then click Save 4 1 2 Windows Server 2008 R2 1 Click Administrative Tool and then click Event Viewer from Control Panel 2 Select the type of log in Windows Logs Applicati...

Страница 33: ...start the system and then follow the procedure below 4 2 1 Windows Server 2012 1 Click Search on the charm bar You can use Run feature by right clicking on the lower left corner of the screen Search R...

Страница 34: ...sult with your sales representative before dumping the memory Dumping the memory while the server is in operating normally may affect the system operation Important When the system restarts after a fa...

Страница 35: ...enance diagnostic tool of Enterprise Linux with Dependable Support product is installed 4 7 Collecting Kernel Dump Linux If an error occurs the dump file should be saved to acquire necessary informati...

Страница 36: ...ower switch When the power cord is connected the management controller is initialized The power cannot be turned on during initialization even if the POWER switch is pressed The POWER LED lights amber...

Страница 37: ...LDER is for this computer or if the motherboard has failed Contact your sales representative Failed to find a file EXPRESSBUILDER disc has stains or cracks or the optical disk drive is faulty Contact...

Страница 38: ...disk format you need to erase contents of destination disk and create partition again Make backup copy of user data in advance and then create a new partition Did you configure the RAID Controller For...

Страница 39: ...PIs Remote Server Administration Tool Role Administration Tools Web Server IIS Tools The features listed above are activated because they are required for the installation of IIS basic features The Te...

Страница 40: ...If the RAID Controller is not recognized as connected although the above action has been taken the RAID Controller may be faulty Contact the maintenance service company with which you signed up or the...

Страница 41: ...authentication The above message is an example of request for license authentication The message displayed on screen may differ from this depending on the license 5 5 When STOP Error Occurs Cannot tur...

Страница 42: ...yed on Virtual Disks Properties Policies Write on WebBIOS If an extra battery is faulty is not connected or insufficiently charged the Cache Mode is changed to WThru Write Through even if you specify...

Страница 43: ...ery temperature to rise temporarily This event temporarily stops the refresh operation so the battery temperature drops and the refresh operation resumes However it may take time till the temperature...

Страница 44: ...may be displayed per controller in Device Manager It is not a problem in operating the system To display correct controller name run the following command stored in the EXPRESSBUILDER DVD and reboot...

Страница 45: ...board for details to make correct settings Some devices connected to the serial or parallel port or USB port may require I O port address or operation mode settings Refer to the manual that comes with...

Страница 46: ...alled Also verify that protocol such as TCP IP or various services have been properly specified Are transfer rate settings correct Verify that the transfer rate and duplex mode are the same as those o...

Страница 47: ...t Some software requires administrator authority or needs to be operated on the server Run on the appropriate environment Confirm the settings of Regional and Language Options Set the language setting...

Страница 48: ...he SYSTEM switch to turn off the server SYSTEM POWER LED is off 2 Use a 100 mm long metal pin that is 1 2 mm in diameter or uncoil a thick paper clip and insert it into the forced eject hole at the fr...

Страница 49: ...ED may light amber Those registered error messages are logs accompanying power failure so there is no problem as to the system Turn off the SYSTEM STATUS LED by performing Clear All Faults to clear fa...

Страница 50: ...s does not start correctly you can recover it using the feature of the Windows installation disc To run this feature start the installation disc and then choose Repair your computer in Windows Setup w...

Страница 51: ...mory and restarts the server Note To reset the server when it is not frozen make sure that no processing is in progress 7 2 BMC Reset Press the BMC RESET Switch only if a problem occurs in EXPRESSSCOP...

Страница 52: ...server for at least 4 seconds The power is forcibly turned off To turn on the power back again wait at least 40 seconds after turning off the power Note If the remote power on function is used cycle t...

Страница 53: ...ms are tested in System Diagnostics Memory CPU cache memory Hard disk drive Ether port Serial port Important When executing the system diagnostics be sure to disconnect LAN cable Executing the system...

Страница 54: ...menu Then select Save Exit menu system is rebooted Note Restore previous boot option after system diagnostics completed If the Maintenance Mode is set to Enable the following screen is displayed Sele...

Страница 55: ...rm that device configuration is correct and all the devices are recognized Device Configuration Information SOL Serial Device Configuration Information VGA Please confirm the devices CPU Information C...

Страница 56: ...1 minute If you execute the test on VGA screen the execution status is displayed every 1 second Execution Status SOL Serial Execution Status VGA Are you sure you want to execute the test 1 Execute 2 C...

Страница 57: ...HDD Slot1 HUC151414CSS600 HDD1 PASS 106 7 SAS2 8 Port1 9 PCI3 10 Port1 eth0 031 ETH PASS 10 11 PCI4 12 Port1 eth1 041 ETH PASS 11 13 Port2 eth2 042 ETH PASS 11 14 Port3 eth3 043 ETH PASS 10 15 Port4...

Страница 58: ...rminal software of destination and then start save process according to on screen instruction Select Log Operation SOL Serial Select Log Operation VGA Save the result file Select the Log Operation 1 S...

Страница 59: ...8 2 5 Exiting System Diagnostics Exit System Diagnostics Select Reboot or Shutdown Exit menu SOL Serial Exit menu VGA This completes System Diagnostics Please select next action 1 Attempt to retry the...

Страница 60: ...ype the following menu is displayed 4 Select BMC Configuration or BMC Configuration Initialization to start each feature For details see the next section 9 2 Features of Offline Tools 9 2 Features of...

Страница 61: ...ached to the server 5 EXPRESSSCOPE Engine SP3 Describes EXPRESSSCOPE Engine SP3 6 NEC ESMPRO Describes NEC ESMPRO Agent and NEC ESMPRO Manager applications to manage and monitor the server 7 NEC Produ...

Страница 62: ...er POST and the Main menu appears Note If Maintenance Mode is enabled pressing the F2 key does not launch SETUP and the Boot Selection menu appears In addition a message The system is in Maintenance M...

Страница 63: ...n Port enabled other than Disabled English is automatically selected At that time you cannot change setting of System Language If BIOS Redirection Port is set to Disabled the language set in this opti...

Страница 64: ...es 1 2 2 Advanced If you move the cursor to Advanced the Advanced menu appears For the menus that show a to their left select a menu and press the Enter key to display its submenu Express5800 A1040b A...

Страница 65: ...cess from memory to cache to either Enabled or Disabled Execute Disable Bit Disabled Enabled Enable or disable Execute Disable Bit feature This option is displayed only when the installed processor su...

Страница 66: ...number of active cores in Processors 1 to 4 Max Cores Shows the maximum number of cores in Processors 1 to 4 L2 Cache RAM Shows the secondary cache size of Processors 1 to 4 L3 Cache RAM Shows the ter...

Страница 67: ...ture This option is displayed only when the installed processor supports this feature OS Performance Tuning Enabled Disabled Specify whether Performance Tuning by OS is allowed or not Energy Performan...

Страница 68: ...tomatically set depending on memory configuration Refer to Chapter 2 1 14 2 Memory Clock in User s Guide for the relation of the memory frequency and memory configuration NUMA Disabled Enabled Enable...

Страница 69: ...Supported is displayed when mirroring feature is available in the current memory configuration Sparing Supported Not Possible Supported is displayed when sparing feature is available in the current me...

Страница 70: ...ce L0s is selected the energy saving level is set to L0s MMIOH Disabled Enabled Enable or disable MMIOH Memory Mapped I O Size over 4GB Fixed PCI Bus F O Disabled Enabled Specify whether the fixed PCI...

Страница 71: ...or disable EFI OpROM PCI1 16 Slot Option ROM Disabled Enabled Slots PCI3 to PCI16 are disabled at shipment Enable or disable the option ROM on each PCI slot Factory settings Note If RAID Controller L...

Страница 72: ...ubmenu For details about the options see the table below Option Parameter Descriptions PCI1 16 LinkSpeed Limit 2 5 GT s 5 0 GT s 8 0 GT s Specify the upper limit of link speed of each PCI slot Factory...

Страница 73: ...QPI link speed VT d Disabled Enabled Enable or disable Intel R Virtualization Technology for Directed I O feature Virtualization of I O feature This option is displayed only when the installed proces...

Страница 74: ...wn below For the menu that has on the left move the cursor to it and then press the Enter key to show its submenus For details about the options see the table below Option Parameter Descriptions SATA...

Страница 75: ...SATA Information submenu For details about the options see the table below display only Option Parameter Descriptions SATA Port Shows a device connected to SATA port Factory settings Express5800 A104...

Страница 76: ...see the table below Option Parameter Descriptions Device Reset Timeout 10 sec 20 sec 30 sec 40 sec Specify the timeout period when Start Unit command is issued to USB Mass Storage Device Controller T...

Страница 77: ...external serial port for connecting with SUV cable Serial A Base I O 3F8h 2F8h 3E8h 2E8h Specify the base I O address for serial port A Serial A Interrupt IRQ 4 IRQ 3 Specify the interrupt for serial...

Страница 78: ...nager and options for connection shown below are displayed Terminal Type VT100 VT UTF8 PC ANSI Select the terminal type Baud Rate 9600 19200 57600 115200 Specify baud rate Data Bits 7 8 Specify data b...

Страница 79: ...the menu screen shown below For details about the options see the table below Option Parameter Descriptions iSCSI Initiator Name Alphanumeric characters Specify iSCSI Initiator Name with IQN format Ex...

Страница 80: ...e table below Option Parameter Descriptions MAC xx xx xx xx xx xx Displays MAC addresses of ports on network card subject to iSCSI boot Select a port and press the Enter key to display submenu to set...

Страница 81: ...Number IP address format Specify IP address of iSCSI Initiator Example 192 168 1 1 Initiator Subnet Mask Number IP address format Specify subnet mask of Initiator Example 255 255 255 0 Gateway Number...

Страница 82: ...ing is applied when system is restarted Back to Previous Page Return to iSCSI Configuration submenu Factory settings b Delete an Attempt submenu Delete an Attempt submenu displays list of Attempts alr...

Страница 83: ...ic character Attempt name Change Attempt order Press the Enter key to display list of Attempts Select an Attempt you want to change order and press or key to change its order Commit Changes and Exit S...

Страница 84: ...Descriptions Password Configuration Administrator Password Up to 20 alphanumeric characters When the Enter key is pressed the password entry screen to set administrative right is displayed This passw...

Страница 85: ...d Enabled Enable or disable the remote keyboard remote keyboard and virtual media features supported by BMC When this option is set to Disabled System BIOS update through BMC cannot be used Trusted Co...

Страница 86: ...TXT Support is set to Enabled Current TPM Status Information TPM Enabled Status Enabled Disabled Shows the cuurent status of TPM feature display only This option is displayed only when TPM Support is...

Страница 87: ...Agent must be installed on OS If starting up an OS on which it is not installed disable this feature Boot Monitoring Time Number Specify boot monitoring timeout Allowable value is between 1 and 60 min...

Страница 88: ...oting when POST detects an error until user s response is made When set to Disabled continues OS booting regardless of user s response even if an error is detected during POST Power Switch Inhibit Dis...

Страница 89: ...ber of the system System Serial Number Shows the serial number of the system Chassis Part Number Shows the part number of chassis Chassis Serial Number Shows the serial number of chassis Management LA...

Страница 90: ...ursor to Power Control Configuration and then press the Enter key to show its submenus For details about the options see the table below Option Parameter Descriptions PSU Redundancy N N 1 2N Specify t...

Страница 91: ...ard Setup Prompt Timeout Number Specify the time until the F2 is pressed to launch SETUP The factory setting time is 0 minimum Boot Mode Configuration Boot Mode UEFI Mode Legacy Mode Specify the boot...

Страница 92: ...e Boot Option 4 USB Key Boot Option 5 Hard Disk Drive Boot Option 6 USB Built in EFI Shell Boot Option 7 USB Hard Disk Drive Boot Option 8 Network Drive If a bootable device has been set to Disabled c...

Страница 93: ...Discard Changes The changes are discarded and the settings are reset to the one at startup of SETUP utility e Load Setup Defaults This option resets all values in the SETUP utility to the default set...

Страница 94: ...e installed in the environment where the power consumption is limited For settings information refer to Chapter 3 7 7 1 BMC 5 ECO in User s Guide or NEC ESMPRO Manager online help 2 1 Notes on Using W...

Страница 95: ...idcmd Adapter RAID Controller RAID Controller Virtual Drive Logical Drive Logical Drive Drive Group Disk Array Disk Array Drive Physical Device Physical Device Tips raidcmd is a command provided by Un...

Страница 96: ...g values of WebBIOS Display levels of Universal RAID Utility Rebuild priority 80 to 100 High 31 to 79 Middle 0 to 30 Low Patrol Read priority 80 to 100 High 31 to 79 Middle 0 to 30 Low Consistency Che...

Страница 97: ...ning Autorun Menu shown in Chapter 2 4 2 Menus of EXPRESSBUILDER 3 Autorun Menu appears Internal Flash Memory optional If Internal Flash Memory is installed in the server EXPRESSBUILDER can be started...

Страница 98: ...rs 10 seconds later 2 Home Menu Operate Home Menu using the mouse or keyboard The following menus are included a Setup You can configure RAID array or install Windows or Linux easily For details about...

Страница 99: ...ed software using Autorun Menu Adobe Reader is required to view or print manuals Integrated Installation You can easily install Starter Pack or applications using this feature If you want to uninstall...

Страница 100: ...en using Internal Flash Memory Starter Pack is usually installed from Autorun Menu Tips Starter Pack is automatically installed when Windows is installed by EXPRESSBUILDER 2 RAID Configuration Data Sa...

Страница 101: ...can be started by pressing F3 key F3 Internal Flash Memory is displayed on the screen Not connected EXPERSSBUILDER cannot be started by pressing F3 key F3 Internal Flash Memory is not displayed on th...

Страница 102: ...e Connecting the management LAN port to your network enables you to do the following from a remote site via a Web browser and SSH client Managing the server remotely Operating KVM keyboard video and m...

Страница 103: ...he RAID system of the server To use these features install the bundled software for the server such as NEC ESMPRO Agent For details see NEC ESMPRO Manager Installation Guide or online help 6 4 NEC ESM...

Страница 104: ...stall the downloaded packages easily by using NEC ExpressUpdate For details see NEC ExpressUpdate Agent Installation Guide in EXPRESSBUILDER Tips Updates are available for some firmware and software t...

Страница 105: ...nd Product Info is stored in a compressed zip file Tips Log on to Windows with an account that has an administrator privilege The installation drive requires a free space of at least 2 5 GB 7 2 Usage...

Страница 106: ...niversal RAID Utility refer to Universal RAID Utility in Installation Guide Windows or Installation Guide Linux Refer to Universal RAID Utility User s Guide in EXPRESSBUILDER for more information abou...

Страница 107: ...es 9 Express Report Service Express Report Service HTTPS For details about Express Report Service Express Report Service HTTPS see Express Report Service Express Report Service HTTPS Installation Guid...

Страница 108: ...hapter 2 Convenient Features 10 Express Report Service MG For details about Express Report Service MG see Express Report Service MG Installation Guide in EXPRESSBUILDER Express5800 A1040b A2040b A2020...

Страница 109: ...ssages for errors detected by a self diagnostic test called POST 2 List of Windows Event Logs Shows a list of Windows event logs 3 Accessing Data for Electrical Power Temperature and Processor Utiliza...

Страница 110: ...aits for user interruption keyboard entry after displaying error message In this case press F1 to resume boot process or F2 to launch SETUP The following table lists error messages and the actions to...

Страница 111: ...or detailed information about Memory Riser of which Mirroring is disabled refer to Activity Log or Memory Information of SETUP 0005E03B One or more MR were Rank Sparing disabled An error was detected...

Страница 112: ...earing Flash ROM After that change destination to backup area by fault tolerant feature and process is ongoing 0001E314 CPU Internal Error was detected L0 I Cache An error was detected in CPU cache 00...

Страница 113: ...MR were disabled due to failure MR is degraded due to failure 0005E2E6 One or more DIMM were disabled due to failure DIMM is degraded due to failure 0006E2E7 PCH was disabled due to failure PCH is deg...

Страница 114: ...D Line Cause Solution XX POST Started Displayed when POST starts This is not an error XX BIOS Rev XXXX Displayed while POST is running This is not an error POST Completed Successfully Displayed when P...

Страница 115: ...cted When installing an OS running an OS for the first time or applying Starter Pack If the message appears upon system startup or upon applying Starter Pack there is no problem in system operation 27...

Страница 116: ...ot affect system operation 10010 Microsoft Windows DistributedCOM Error The server xxxxxxxx xxxx xxxx xxxx xxxxxxxxxxxx did not register with DCOM within the required timeout Upon OS Installation Go t...

Страница 117: ...g error occurred 0x79 Your computer will continue to try and obtain an address on its own from the network address DHCP server When installing an OS applying Starter Pack If it is not an event occurs...

Страница 118: ...00 0020 00 00 00 00 00 00 00 00 0028 B7 27 04 00 00 00 00 00 0030 FF FF FF FF 06 00 00 00 yyyy 0038 40 00 00 00 00 00 00 00 0040 00 00 06 12 08 00 00 10 0048 00 00 00 00 3C 00 00 00 0050 00 00 00 00...

Страница 119: ...startup if a team is configured however there is no problem in operation of LAN driver 63 Microsoft Windows WMI Warning A provider BnxWmiProvider has been registered in the Windows Management Instrum...

Страница 120: ...another server that has a floppy disk drive while operating Windows Server 2008 R2 Go to the following Microsoft website for details http support microsoft com kb 2003968 en us Applications and Servic...

Страница 121: ...hen the system is used This event is logged when activating Windows Server 2008 R2 Hyper V but this event does not affect system operation 14100 Microsoft Windows Hyper V VMMS Warning Shut down physic...

Страница 122: ...r vbs Start Script Option Explicit Prepare for IPMI Driver Dim osvc oclass Dim oinstance oipmi set osvc getobject winmgmts root wmi set oclass osvc get microsoft_ipmi for each oinstance in osvc instan...

Страница 123: ...Power vbs Execution result Completion Code 0x0 Power Consumption 76 watts The power consumption is 76 watts Tips Power consumption readings may not be acquired depending on the power supply configura...

Страница 124: ...onseData 3 256 outparams ResponseData 2 Reserve SDR Repository oinparams networkfunction ha oinparams lun 0 oinparams responderaddress h20 oinparams command h22 oinparams requestdatasize 0 Dim Reserve...

Страница 125: ...t Sendor Reading Dim sensorData rawData currentValue oinparams networkfunction h4 oinparams lun 0 oinparams responderaddress h20 oinparams command h2d oinparams requestdata array sensorNum oinparams r...

Страница 126: ...rv_ms rc_ls rc_ms 48 idlength oinparams requestdatasize 6 set outsdridstring oipmi execmethod_ requestresponse oinparams tmpMessage ID String For j 3 to idlength 2 tmpMessage tmpMessage Chr outsdrids...

Страница 127: ...cessor objectSet objRefresher Refresh Dim first first true Do For each intProcessorUse in objProcessor If first Then If intProcessorUse Name _Total Then first false End If else Wscript Echo Proc intPr...

Страница 128: ...penIPMI tools version rpm Execution example ipmitool raw 0x3e 0x0b Execution result 4C 00 Power consumption is given by calculating the 2 byte 16 bits output value The second value 0x00 15 8 The first...

Страница 129: ...ok 48 degrees C CPU1_DIMM2 Temp 41h ok 46 degrees C CPU1_DIMM3 Temp 42h ok 49 degrees C CPU1_DIMM4 Temp 43h ns No Reading CPU1_DIMM5 Temp 44h ns No Reading CPU1_DIMM6 Temp 45h ns No Reading P1 Therm C...

Страница 130: ...intr s 17 59 30 all 1 23 0 04 0 42 2 69 0 03 0 10 0 00 95 49 1086 42 17 59 30 0 0 42 0 00 0 58 0 76 0 00 0 00 0 00 98 24 666 34 17 59 30 1 0 41 0 00 0 29 1 09 0 00 0 00 0 00 98 21 0 00 17 59 30 2 2 17...

Страница 131: ...ERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Copyright c 2004 2007 Intel Corporation All rights reserved This program and the accompanyin...

Страница 132: ...ut prior written permission of the OpenSSL Project 6 Redistributions of any form whatsoever must retain the following acknowledgment This product includes software developed by the OpenSSL Project for...

Страница 133: ...orse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRA...

Страница 134: ...n THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR...

Страница 135: ...e software or use pieces of it in new free programs and that you know you can do these things To protect your rights we need to make restrictions that forbid anyone to deny you these rights or to ask...

Страница 136: ...t refer to this License and to the absence of any warranty and give any other recipients of the Program a copy of this License along with the Program You may charge a fee for the physical act of trans...

Страница 137: ...de to be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange or c Accompany it with the information you received as to the offer to distribute c...

Страница 138: ...ugh you then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Program If any portion of this section is held invalid or unenforceable under...

Страница 139: ...ECTIVE YOU ASSUME THE COST OF ALL NECESSARY SERVICING REPAIR OR CORRECTION 12 IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WILL ANY COPYRIGHT HOLDER OR ANY OTHER PARTY WHO MAY...

Страница 140: ...gram if necessary Here is a sample alter the names Yoyodyne Inc hereby disclaims all copyright interest in the program Gnomovision which makes passes at compilers written by James Hacker signature of...

Страница 141: ...ts with a two step method 1 we copyright the library and 2 we offer you this license which gives you legal permission to copy distribute and or modify the library To protect each distributor we want t...

Страница 142: ...e difference between a work based on the library and a work that uses the library The former contains code derived from the library whereas the latter must be combined with the library in order to run...

Страница 143: ...the modified Library refers to a function or a table of data to be supplied by an application program that uses the facility other than as an argument passed when the facility is invoked then you must...

Страница 144: ...y the source code from the same place satisfies the requirement to distribute the source code even though third parties are not compelled to copy the source along with the object code 5 A program that...

Страница 145: ...recompile the application to use the modified definitions b Use a suitable shared library mechanism for linking with the Library A suitable mechanism is one that 1 uses at run time a copy of the libr...

Страница 146: ...or distributing the Library or any work based on the Library you indicate your acceptance of this License to do so and all its terms and conditions for copying distributing or modifying the Library or...

Страница 147: ...that version or of any later version published by the Free Software Foundation If the Library does not specify a license version number you may choose any version ever published by the Free Software F...

Страница 148: ...the License or at your option any later version This library is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS...

Страница 149: ...hout prior written permission For written permission please contact openssl core openssl org 5 Products derived from this software may not be called OpenSSL nor may OpenSSL appear in their names witho...

Страница 150: ...n the documentation and or other materials provided with the distribution 3 All advertising materials mentioning features or use of this software must display the following acknowledgement This produc...

Страница 151: ...ANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDE...

Страница 152: ...ICULAR PURPOSE THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU SHOULD THE PROGRAM PROVE DEFECTIVE YOU ASSUME THE COST OF ALL NECESSARY SERVICING REPAIR OR CORRECTION IN NO...

Страница 153: ...r without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following di...

Страница 154: ...VICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY W...

Страница 155: ...ARRANTIES OF MERCHANTABILITY AND FITNESS IN NO EVENT SHALL TODD C MILLER BE LIABLE FOR ANY SPECIAL DIRECT INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE DATA OR...

Страница 156: ...rved Redistribution and use in source and binary forms with or without modification are permitted only as authorized by the OpenLDAP Public License A copy of this license is available in the file LICE...

Страница 157: ...plied warranties of merchantibility and fitness for any particular purpose Copyright c 1987 Regents of the University of California All rights reserved Redistribution and use in source and binary form...

Страница 158: ...ation Portions of the documentation and some code used as part of the build process might fall under other licenses The details here are unclear We do not worry about the licensing of the documentatio...

Страница 159: ...ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH...

Страница 160: ...384 512 implementation Last update 06 15 2005 Issue date 06 15 2005 Copyright C 2005 Olivier Gay olivier gay a3 epfl ch All rights reserved Redistribution and use in source and binary forms with or w...

Страница 161: ...m the Work and for which the editorial revisions annotations elaborations or other modifications represent as a whole an original work of authorship For the purposes of this License Derivative Works s...

Страница 162: ...xcluding those notices that do not pertain to any part of the Derivative Works in at least one of the following places within a NOTICE text file distributed as part of the Derivative Works within the...

Страница 163: ...armless for any liability incurred by or claims asserted against such Contributor by reason of your accepting any such warranty or additional liability END OF TERMS AND CONDITIONS APPENDIX How to appl...

Страница 164: ...et forth in this Agreement However any and all rights underlying in the Licensed Program shall be held by the Licensor In no sense is this Agreement intended to transfer any right relating to the Lice...

Страница 165: ...the preceding Article the Recipient shall meet all of the following conditions 1 The Recipient may not change the name of the Licensed Program 2 The Recipient may not alter or otherwise modify the Li...

Страница 166: ...or its affiliates All rights reserved Use is subject to license terms Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer Redist...