1. POST Error Message
Chapter 3 Appendix
(1)
Error messages
Error Message
Cause
Solution
C000C105
BMC SEL Area is full.
Free space for storing System Event
Log is insufficient.
Perform BMC SEL Clear from web
browser of EXPRESSSCOPE Engine
SP3.
0001E35C
Setup mistake was detected.
(COPT/NUMA)
Dynamic is specified for Core
Optimization Mode on web console,
but NUMA is disabled in BIOS
SETUP. Dynamic COPT cannot work
with NUMA disabled.
Specify [Enabled] for NUMA in BIOS
SETUP to use Dynamic COPT
feature.
0005E373
Setup value was changed.
(Memory Voltage/Auto)
An error was detected in
configuration control of DIMM. Setup
value of Memory Voltage was
changed to Auto.
Review the setting of Memory
Voltage in SETUP. Auto is
recommended.
0005E374
Setup value was changed.
(Memory Frequency/Auto)
An error was detected in
configuration control of DIMM. Setup
value of Memory Frequency was
changed to Auto.
Review the setting of Memory
Frequency in SETUP. Auto is
recommended.
0005E375
Setup value was changed.
(Memory RAS Mode/Independent
to Lock Step)
An error was detected in
configuration control of DIMM. Setup
value of Memory RAS Mode was
changed to Lock Step.
Review the setting of Memory RAS
Mode in SETUP.
0005E376
Setup value was changed.
(Memory RAS Mode/Lock Step to
Independent)
An error was detected in
configuration control of DIMM. Setup
value of Memory RAS Mode was
changed to Independent.
Review the setting of Memory RAS
Mode in SETUP.
0005E03A
One or more MR were Mirroring
disabled.
An error was detected in
configuration check of Memory
Mirroring. Mirroring was disabled on
one or more Memory Riser.
Review the configuration of DIMM.
For detailed information about
Memory Riser of which Mirroring is
disabled, refer to Activity Log or
Memory Information of SETUP.
0005E03B
One or more MR were Rank
Sparing disabled.
An error was detected in
configuration check of Memory
Sparing. Sparing was disabled on
one or more Memory Riser.
Review the configuration of DIMM.
For detailed information about
Memory Riser of which Sparing is
disabled, refer to Activity Log or
Memory Information of SETUP.
0001E380
Setup mistake was detected. (MR
Add/NUMA)
Dynamic is specified for Spare
Memory Configuration Mode on web
console of EXPRESSSCOPE Engine
SP3, but NUMA is disabled in BIOS
SETUP.
Specify [Enabled] for NUMA in BIOS
SETUP to use MR Hot-Add.
0006E00A
NVRAM (SPI Flash) device register
error was detected when trying to
program data.
A device error (write error to HW
register) occurred while writing into
Flash ROM. (After that change
destination to backup area by fault
tolerant feature, and process is
ongoing.)
Contact your service representative.
0006E00C
NVRAM (SPI Flash) SPI cycle
timeout was detected when trying
to program
data.
A timeout error occurred while writing
into Flash ROM. (After that change
destination to backup area by fault
tolerant feature, and process is
ongoing.)
0006E00E
NVRAM (SPI Flash) write
operation timeout was detected
when trying to
program data.
A timeout error occurred while
waiting for completion of
writing into Flash ROM. (After that
change destination to backup area
by fault tolerant feature, and process
is ongoing.)
0006E010
NVRAM (SPI Flash) verify error
was detected when trying to
program data.
A verify error (inconsistency between
read and write data) occurred while
writing into Flash ROM. (After that
change destination to backup area
by fault tolerant feature, and process
is ongoing.)
Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide
111