Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112686
User Action:
1. Ensure the populated power supplies is with the same type.
2. If the event persists, please consult with technical service.
•
180702F4: Thermal Overheat: Chassis, transition to Critical from less severe was asserted.
The enclosure encounters thermal condition, all fans are requested to ramp up to retain enough airflow for
cooling the enclosure.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112692
User Action:
1. Ensure the room temperature remains at the required level.
2. Ensure all fan modules are installed and operating properly.
3. If the event persists, please consult with technical service.
•
180702F5: Thermal Protect: Chassis, transition to Critical from less severe was asserted.
The enclosure encounters thermal condition, all fans are requested to ramp up to retain enough airflow for
cooling the enclosure.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112693
User Action:
1. Ensure the room temperature remains at the required level.
2. Ensure all fan modules are installed and operating properly.
3. If the event persists, please consult with technical service.
•
180702F6: Encl No Perm: Chassis, transition to Critical from less severe was asserted.
The power permission of whole enclosure has been locked.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112694
User Action:
For DA240 enclosure only, ensure all system fans are proper installed.
•
180702F7: Encl Cap Low: Chassis, transition to Critical from less severe was asserted.
The restored power cap value is invalid since it is lower than current power capping boundary.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 403112695
User Action:
Re-configure the enclosure power capping setting from web GUI or IPMI command.
•
180702F8: Encl Cap Fail: Chassis, transition to Critical from less severe was asserted.
Unable to apply enclosure power capping.
.
31
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......