Table 3. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSPPW0035M
Numeric sensor [NumericSensorElementName] going low (lower
critical) has asserted.
Error
FQXSPPW0047M
Numeric sensor [NumericSensorElementName] going high (upper
critical) has asserted.
Error
FQXSPPW0061M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
Error
FQXSPPW0063M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
Error
FQXSPSD0001L
The [StorageVolumeElementName] has been disabled due to a
detected fault.
Error
FQXSPSD0002L
Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has been
disabled due to a detected fault.
Error
FQXSPSD0005L
Array [ComputerSystemElementName] is in critical condition.
Error
FQXSPSD0006L
Array [ComputerSystemElementName] has failed.
Error
FQXSPSD0007L
Array critical asserted on drive [arg1] in the enclosure/chassis (MTM-
S/N: [arg2]).
Error
FQXSPSD0008L
Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
Error
FQXSPSE4000I
Certificate Authority [arg1] has detected a [arg2] Certificate Error.
Error
FQXSPSE4006I
SSL data in the Management Controller [arg1] configuration data is
invalid. Clearing configuration data region and disabling SSL.
Error
FQXSPSR0001N
Sensor [SensorElementName] has transitioned to non-recoverable
from a less severe state.
Error
FQXSPUN0019M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
Error
FQXSPUN0023N
Sensor [SensorElementName] has transitioned to non-recoverable.
Error
FQXSPUP0007L
Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName].
Error
FQXSPUP4000I
Please ensure that the Management Controller [arg1] is flashed with
the correct firmware. The Management Controller is unable to match
its firmware to the server.
Error
FQXSPUP4003I
[arg1] firmware mismatch internal to system [arg2]. Please attempt to
flash the [arg3] firmware.
Error
FQXSPUP4004I
XCC firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the XCC firmware to the same level on all
nodes/servers.
Error
FQXSPUP4005I
FPGA firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the FPGA firmware to the same level on all
nodes/servers.
Error
List of XClarity Controller events
This section lists all messages that can be sent from the XClarity Controller.
•
FQXSPBR4000I: Management Controller [arg1]: Configuration restored from a file by user [arg2].
61
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......