Note:
It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings
-> Devices and I/O Ports ->PCIe Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
4. If the problem persists, collect Service Data logs.
•
FQXSFIO0020J: PCIe Isolation has occurred in PCIe slot [arg1]. The adapter may not operate
correctly.
Severity: Info
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure the PCIe that the PCIe device is installed in the compatible
PCIe slot and a compatible cable is used. If not, performance of this device might be impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSFIO0021J: PCIe Error Recovery has occurred in physical [arg1] number [arg2]. The [arg3] may
not operate correctly.
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve
that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible
PCIe slot or bay and a compatible cable is used. If not, performance of this device might be
impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSFIO0022J: PCIe Link Width has degraded from [arg1] to [arg2] in PCIe slot [arg3].
Severity: error
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device is installed in the compatible PCIe slot and
a compatible cable is used. If not, performance of this device might be impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
•
FQXSFIO0023J: PCIe Link Speed has degraded from [arg1] to [arg2] in PCIe slot [arg3].
184
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......