3. If the event persists, reset the BMC on indicated compute node.
4. If the event persists, ensure the indicated compute node is completely power off and then reseat it.
(Service technician only)
5. If the event persists, replace the indicated compute node. (Service technician only)
6. If the event persists, please consult with technical service.
•
2107084C: Node 1 Reset: Slot Or Connector, Informational was asserted.
User performs BMC reset on the indicated compute node.
Severity: Information
Alert Category: Node - Node event
SNMP Trap ID: 554109004
User Action:
Information only; no action is required.
•
2107084D: Node 2 Reset: Slot Or Connector, Informational was asserted.
User performs BMC reset on the indicated compute node.
Severity: Information
Alert Category: Node - Node event
SNMP Trap ID: 554109005
User Action:
Information only; no action is required.
•
2107084E: Node 3 Reset: Slot Or Connector, Informational was asserted.
User performs BMC reset on the indicated compute node.
Severity: Information
Alert Category: Node - Node event
SNMP Trap ID: 554109006
User Action:
Information only; no action is required.
•
2107084F: Node 4 Reset: Slot Or Connector, Informational was asserted.
User performs BMC reset on the indicated compute node.
Severity: Information
Alert Category: Node - Node event
SNMP Trap ID: 554109007
User Action:
Information only; no action is required.
•
21070858: Node 1 Reseat: Slot Or Connector, Informational was asserted.
User performs an AC cycle on the indicated compute node.
Severity: Information
Alert Category: Node - Node event
SNMP Trap ID: 554109016
User Action:
Information only; no action is required.
•
21070859: Node 2 Reseat: Slot Or Connector, Informational was asserted.
User performs an AC cycle on the indicated compute node.
38
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......