Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0524
User Action:
Using XClarity Controller web, LSA or Storcli to check the status of every virtual disk on your system and
resolve the problem on the faulty virtual disk(s).
•
FQXSPSR2001I: Sensor [SensorElementName] has deasserted the transition to non-recoverable
from a less severe state.
This message is for the use case when an implementation has detected that the Sensor transition to non-
recoverable from less severe has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0525
User Action:
Information only; no action is required
•
FQXSPSS4000I: Management Controller Test Alert Generated by [arg1].
This message is for the use case where a user has generated a Test Alert.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0040
User Action:
Information only; no action is required.
•
FQXSPSS4001I: Server General Settings set by user [arg1]: Name=[arg2], Contact=[arg3],
Location=[arg4], Room=[arg5], RackID=[arg6], Rack U-position=[arg7], Address=[arg8].
A user configured the Location setting
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0080
User Action:
Information only; no action is required.
•
FQXSPSS4002I: License key for [arg1] added by user [arg2].
A user installs License Key
158
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......