If the NMI button on the node operator panel has not been pressed, complete the following steps:
1. Reboot the system.
2. If the error still exists, then collect serivce log and contact Lenovo support.
•
FQXSPIO0004L: A bus timeout has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Timeout.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0224
User Action:
Complete the following steps:
1. Please reseat the processor and reboot the compute node.
2. If the problem still exists, (service technician) please remove the existing components which have
been installed in the node tray. Then, replace the defective node tray and re-install these components
into the new node tray.
3. If the problem still exist, contact Lenovo support.
•
FQXSPIO0006N: A software NMI has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Software NMI.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0228
User Action:
Complete the following steps to solve:
1. Check the event log in system event log to resolve any issues related the NMI.
2. If the problem still exists, please contact Lenovo support.
•
FQXSPIO0007N: A PCI PERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI PERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0232
User Action:
Complete the following steps to solve:
1. Reseat the adapter or the other slot.
2. If the problem still exists, replace the adapter.
85
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......