Table 5. Events organized by severity (continued)
Event ID
Message String
Severity
FQXPMER0006M
Failed to load XCC factory default settings
Error
FQXPMSD0001M
HDD Test was interrupted by the host with a hardware or software
reset
Error
FQXPMSD0002M
A fatal error or unknown test error occurred while the device was
executing its self-test
Error
FQXPMSD0003M
self-test completed having a test element that failed and the test
element that failed is not known.
Error
FQXPMSD0004M
self-test completed having the electrical element of the test failed.
Error
FQXPMSD0005M
self-test completed having the servo (and/or seek) test element of the
test failed.
Error
FQXPMSD0006M
self-test completed having the read element of the test failed.
Error
FQXPMSD0007M
Hard Drive(s) not found
Error
FQXPMSD0008M
UEFI is not ready for LXPM to send command to test hard drive.
Error
FQXPMSD0009M
Device error is occurred when LXPM send command to test hard
drive.
Error
FQXPMSD0010M
uEFI is timeout while LXPM send command to test hard drive.
Error
FQXPMSD0011M
The hard drive is not supported by uEFI while LXPM send command
to test hard drive.
Error
FQXPMUP0201M
BMC communication failed: EMMC2USB mount failure. Failed to
update the firmware
Error
FQXPMUP0202M
Transfer the update package error. Failed to update the firmware
Error
FQXPMUP0203M
BMC communication failed: EMMC2USB unmount failure. Failed to
update the firmware
Error
FQXPMUP0204M
BMC communication failed: Execute the update cmd failure. Failed to
update the firmware
Error
FQXPMUP0205M
BMC communication failed: Get the update status failure.Failed to
update the firmware
Error
FQXPMUP0206M
The level of the update package is too old. Failed to update the
firmware.
Error
FQXPMUP0207M
The update package is invalid. Failed to update the firmware.
Error
FQXPMUP0208M
Failed to execute reboot BMC command
Error
List of Lenovo XClarity Provisioning Manager V3 events
This section lists all messages that can be sent from the Lenovo XClarity Provisioning Manager V3.
•
FQXPMCL0001K: Bootx64.efi is not found. Failed to Boot OS.
Severity: Warning
User Action:
1. Restart BMC via supported method and reboot the system.
2. If the problem persists, reflash BMC firmware.
214
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......