Table 4. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSFMA0016M
Memory spare copy failed. [arg1]
Warning
FQXSFMA0027M
DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
Warning
FQXSFMA0028M
DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
Warning
FQXSFMA0030K
Intel Optane PMEM DIMM [arg1] Percentage Remaining is less than
[arg2]% and still functioning.
Warning
FQXSFMA0031K
Intel Optane PMEM DIMM [arg1] has reached 1% remaining spares
block and still functioning.
Warning
FQXSFMA0032M
Intel Optane PMEM DIMM [arg1] has no remaining spares block.
Warning
FQXSFMA0033M
Intel Optane PMEM persistent memory interleave set has [arg1]
PMEMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Warning
FQXSFMA0034M
DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set should be moved to DIMM slot [arg3] in sequence.
Warning
FQXSFMA0035M
Intel Optane PMEM interleave set should have [arg1] PMEMs, but
[arg2] PMEMs are missing.
Warning
FQXSFMA0036M
DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set is missing.
Warning
FQXSFMA0037G
Intel Optane PMEM interleave set (DIMM [arg1]) is migrated from
another system (Platform ID: [arg2]), these migrated PMEMs are not
supported nor warranted in this system.
Warning
FQXSFMA0038K
All Intel Optane PMEMs could not be auto unlocked because of no
passphrase.
Warning
FQXSFMA0039K
One or more Intel Optane PMEMs could not be auto unlocked
because of invalid passphrase.
Warning
FQXSFMA0040K
Invalid Intel Optane PMEM configuration detected. Please verify
PMEM configuration is valid.
Warning
FQXSFMA0041K
Near Memory/Far Memory ratio (1:[arg1].[arg2]) for Intel Optane
PMEM configuration is not in recommended range (1:4 - 1:16).
Warning
FQXSFMA0047M
SPD CRC checking failed on DIMM [arg1]. [arg2]
Warning
FQXSFPU0022G
The TPM configuration is not locked.
Warning
FQXSFPU0023G
Secure Boot Image Verification Failure Warning.
Warning
FQXSFPU0033G
Processor has been disabled.
Warning
FQXSFPU4033F
TPM Firmware recovery is in progress. Please DO NOT power off or
reset system.
Warning
FQXSFPU4035M
TPM Firmware recovery failed. TPM chip may be damaged.
Warning
FQXSFPU4040M
TPM selftest has failed.
Warning
FQXSFPU4043G
TPM Firmware update aborted. System is rebooting...
Warning
FQXSFPU4050G
Failed to update TPM Firmware.
Warning
174
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......