background image

R282-Z93

AMD EPYC™ 7003 DP Server System - 2U 12-Bay GPU sku

User Manual

Rev. 1.0

Содержание R282-Z93

Страница 1: ...R282 Z93 AMD EPYC 7003 DP Server System 2U 12 Bay GPU sku User Manual Rev 1 0 ...

Страница 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Страница 3: ...this user s guide NOTE Pieces of additional information related to the current topic CAUTION Precautionary measures to avoid possible hardware or software problems WARNING Alerts to any damage that might result from doing or not doing specific actions ...

Страница 4: ...server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing CAUTION Do not operate the server for long periods with the access panel open or removed Operat ing the server in this manner results i...

Страница 5: ...ystem is removed from the rack before opening the chassis adding or removing any non hot plug components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the system chassis and disconnect the cables attached to the system before servicing the chassis Otherwise personal injury or equip ment damage can result ...

Страница 6: ... do not have such a tab take care when us ing needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can dam age the contacts inside the jumper causing intermittent problems with the function con trolled by that jumper Take care to grip with but not squeeze the pliers or other tool used to remove a jumper o...

Страница 7: ... Installing the CPU 29 3 5 Removing and Installing Memory 31 3 5 1 Eight Channel Memory Configuration 31 3 5 2 Removing and Installing a Memory Module 32 3 5 3 Processor and Memory Module Matrix Table 32 3 5 4 DIMM Population Table 33 3 6 Removing and Installing the PCIe Riser Card 34 3 7 Installing the Mezzanine Card 36 3 7 1 Installing the OCP 3 0 Mezzanine Card 36 3 7 2 Installing the OCP 2 0 M...

Страница 8: ... 2 16 Intel R I350 Gigabit Network Connection 77 5 2 17 VLAN Configuration 79 5 2 18 MAC IPv4 Network Configuration 81 5 2 19 MAC IPv6 Network Configuration 82 5 3 AMD CBS Menu 83 5 3 1 Valhalla Common Options 84 5 3 2 DF Common Options 87 5 3 3 UMC Common Options 90 5 3 4 NBIO Common Options 92 5 3 5 FCH Common Options 97 5 3 6 NTB Common Options 100 5 3 7 SOC Miscellaneous Control 101 5 4 AMD PB...

Страница 9: ... 9 5 8 2 UEFI Application Boot Priorities 118 5 9 Save Exit Menu 119 5 10 BIOS POST Beep code AMI standard 120 5 10 1 PEI Beep Codes 120 5 10 2 DXE Beep Codes 120 ...

Страница 10: ... 10 This page intentionally left blank ...

Страница 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Страница 12: ...M slot DDR4 memory supported only 8 Channel memory architecture RDIMM modules up to 128GB supported LRDIMM modules up to 128GB supported 3DS RDIMM LRDIMM modules up to 256GB supported Memory speed Up to 3200 2933 MHz Note Follow BIOS setting and memory QVL list if running 3200 Mhz with 2DPC LAN 2 x 1GbE LAN port 1 x Intel I350 AM2 1 x 10 100 1000 management LAN Video Integrated in Aspeed AST2500 2...

Страница 13: ...3 x4 Supports NGFF 2242 2260 2280 22110 cards CPU TDP is limited to 225W if using M 2 device NOTE Support is not provided for mixed GPU populations Storage 12 x 3 5 SATA SAS hot swappable HDD SSD bays from onboard SATA ports 2 5 HDD SSD supported Default configuration supports 12 x SATA drives or 4 x SATA drives 8 x SAS drives via SAS HBA NOTE SAS card is required to support SAS devices Internal I...

Страница 14: ...th SPI interface TPM2 0 kit CTM010 optional System Management Aspeed AST2500 management controller AMI MegaRAC SP X Solution web interface Dashboard JAVA Based Serial Over LAN HTML5 KVM Sensor Monitor Voltage RPM Temperature CPU Status etc Sensor Reading History Data FRU Information SEL Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption P...

Страница 15: ...0 120V 12 2V 81 5A 12Vsb 2 5A 1600W 180 199V 12 2V 131A 12Vsb 2 5A 1800W 200 220V 12 2V 147 5A 12Vsb 2 5A 2000W 221 240V 12V 163 5A 12Vsb 2 5A Operating Properties Operating temperature 10 C to 35 C Operating humidity 8 to 80 non condensing Non operating temperature 40 C to 60 C Non operating humidity 20 to 95 non condensing System Dimension 2U 438 W x 87 H x 730 D mm ...

Страница 16: ...er card Riser CRS2026 PCIe4 0 x16 PCIe4 0 x16 8 x SATAIII PCIe4 0 x16 Intel i350 AM2 PCIe2 0 x2 MDI NCSI 2 x 1G LAN SPI Flash 32 MB Switch VGA COM ASPEED AST2500 MLAN RGMII RTL8211 PHY MAC BMC 8 x SATAIII Switch NCSI Switch LPC OCP 3 0 mezzanine PCIe2 0 x1 PCIe3 0 x4 TPM 8 bay 3 5 2 5 SATA 2 x SlimLine 4i USB HUB GL3523 2 x USB 3 0 rear AMD MILAN Zen3 Core Socket SP3 CPU_0 Riser CRS2014 PCIe x16 A...

Страница 17: ...No Description 1 Front Panel LEDs and Buttons 2 3 5 HDD Bays 3 Front USB 3 0 Ports Refer to section 2 3 Front Panel LEDs and Buttons for a detailed description of the function of the LEDs 1 3 2 HDD 0 HDD 1 HDD 2 HDD 3 HDD 4 HDD 5 HDD 6 HDD 7 HDD 8 HDD 9 HDD 10 HDD 11 ...

Страница 18: ...Type optional 6 Mezzanine Slot for OCP 2 0 Card optional 2 ID Button with LED 7 VGA Port 3 Server Management LAN Port 8 Full Height GPU Card Slot 4 1 GbE LAN Ports 9 Full Height GPU Card Slot 5 USB 3 0 Port x 2 10 Full Height GPU Card Slot Refer to section 2 4 Rear System LAN LEDs for a detailed description of the function of the LEDs ...

Страница 19: ...D Green On Indicates the system is powered on Green Blink System is in ACPI S1 state sleep mode N A Off System is not powered on or in ACPI S5 state power off System is in ACPI S4 state hibernate mode 4 ID Button with LED Blue On Indicates the system identification is active N A Off Indicates the system identification is disabled 5 HDD Status LED Green On Indicates locating the HDD Blink Indicates...

Страница 20: ... include Redundant power module failure Temperature and voltage issue Chassis intrusion N A Off Indicates system is not ready may include POST error NMI error Processor or terminator is missing 7 8 LAN1 2 Active Link LED Green On Indicates a link between the system and the network or no access Green Blink Indicates data trasmission or receiving is occuring N A Off Indicates no data transmission or...

Страница 21: ... Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 1 2 1 2 2 1 ...

Страница 22: ...Hz Green Blinking Power supply firmware updateing mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut down failure OCP OVP fan failure and UVP 1Hz Amber Blinking Power supply warning events where the power supply continues to operate high temp high power high current and slow fan ...

Страница 23: ...emoved HDD Slot LED on Back Panel Green ON 1 OFF Amber OFF OFF RAID configuration via HW RAID Card or SW RAID Card Disk LED Green ON OFF BLINK 2 OFF Amber OFF ON Low Speed 2 Hz OFF OFF Removed HDD Slot Green ON 1 OFF 3 Amber OFF ON 3 LED 2 HDD Present No HDD Green ON OFF NOTE 1 Depends on HBA Utility Spec 2 Blink cycle depends on HDD s activity signal 3 If HDD is pulled out during rebuilding the d...

Страница 24: ...System Appearance 24 This page intentionally left blank ...

Страница 25: ...u are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do...

Страница 26: ... instructions to remove the chassis cover 1 Remove the screw securing the chassis cover 2 Loosen the thumbnail screw securing the chassis cover 3 Push down on the indentations located on the side of the chassis cover 4 Slide the chassis cover to the rear of the system and then remove the cover in the direction of the arrow 5 To reinstall the chassis cover follow steps 1 4 in reverse order 2 3 3 1 ...

Страница 27: ...g and Installing the Fan Duct Follow these instructions to remove the fan duct 1 Lift up to remove the fan duct 2 To reinstall the fan duct align the fan duct with the guiding groove Push down the fan duct until it is firmly seated on the system ...

Страница 28: ...urn off the server before you start installing components may cause serious damage Do not attempt the procedures described in the following sections unless you are a qualified service technician Follow these instructions to install the heat sink 1 Loosen the screws securing the heat sink in place in reverse order 4g3g2g1 2 Lift and remove the heat sink from the system 3 To install the heat sink re...

Страница 29: ...tions unless you are a qualified service technician Follow these instructions to install the CPU 1 Loosen the three captive screws securing the CPU cover in sequential order 1g2g3 2 Flip open the CPU cover 3 Remove the CPU carrier from the CPU frame using the handle on the CPU carrier 4 Using the handle on the CPU carrier insert the new CPU carrier with CPU installed into the CPU frame NOTE Ensure...

Страница 30: ...System Hardware Installation 30 CPU 4 5 7 1 1 3 3 2 2 6 Tighten the CPU cover screws in sequential order 1g2g3 The screw tightening torque 16 1 1 2 kgf cm 14 0 1 0 lbf in ...

Страница 31: ...P0_D0 DIMM_P0_D1 DIMM_P1_N0 DIMM_P1_N1 DIMM_P1_M0 DIMM_P1_M1 DIMM_P1_O0 DIMM_P1_O1 DIMM_P1_P0 DIMM_P1_P1 DIMM_P1_K1 DIMM_P1_K0 DIMM_P1_L1 DIMM_P1_L0 DIMM_P1_J1 DIMM_P1_J0 DIMM_P1_I1 DIMM_P1_I0 Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always...

Страница 32: ...ose the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 5 3 Processor and Memory Module Matrix Table Processor and Memory Module Matrix Table 8 DIMMs CPU CPU0 A1 B1 C1 D1 E1 F1 G1 H1 16 DIMMs CPU0 A1 A0 B1 B0 C1 C0 D1 D0 E1 E0 F1 F0 G1 G0 H1 H0 16 DIMMs CPU0 A1 B1 C1 D1 E1 F1 G1 H1 CPU1 I1 J1 K1 L...

Страница 33: ...ks 3200 LRDIMM 4DR 4 Ranks 3200 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 3DS 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 DIMM Type DIMM Population Max EPYC 7003 DDR Frequency MHz DIMM 0 DIMM 1 RDIMM 1R 3200 1R 1R 2933 2R or 2DR 3200 1R 2R or 2DR 2933 2R or 2DR 2R or 2DR 2933 LRDIMM 4DR 3200 4DR 4DR 2933 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 2S2R 4 Ranks 2S2R 4 Ranks 2933 2S4R 8 Ranks 2S4R 8 Ranks 2933 3DS 2S2R 4...

Страница 34: ...ling as standard To install a PCI card a riser card must be installed Follow these instructions to install a PCIe card 1 Loosen the thumbnail screw securing the riser bracket from the rear side of the system 2 Loosen the two thumbnail screws securing the riser bracket inside the system 3 Lift up the riser bracket out of system 4 Remove the screw securing the slot cover from riser bracket 5 Orient ...

Страница 35: ... 35 System Hardware Installation 4 5 6 7 4 5 6 7 5 6 6 7 7 9 4 ...

Страница 36: ... latch Follow these instructions to install an OCP 3 0 Mezzanine card 1 Remove the two screws securing the OCP 3 0 card slot cover 2 Remove the slot cover from the system 3 Insert the OCP 3 0 card into the card slot ensuring that the card is firmly connected to the connector on the motherboard 4 Tighten the thumbnail screw to secure the OCP 3 0 card in place 5 Reverse steps 3 4 to replace the OCP ...

Страница 37: ...cover from the system 3 Align the screw holes on the OCP 2 0 card with the heads of the stand off screws ensuring that the ports on the card are properly fitted into the rear panel of the system 4 Press down on the OCP 2 0 card so that the connector on the card is firmly connected to the connector on the motherboard and then secure three screws on the card 5 Reverse steps 3 4 to replace the OCP 2 ...

Страница 38: ...correctly Make sure that the hard disk drive is connected to the connector on the backplane Follow these instructions to install a 3 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the HDD tray 4 Align the hard disk drive with the positioning stud on the HDD tray 5 Slide the hard disk drive into the HDD tray 6 Re...

Страница 39: ... button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the HDD tray 4 Align the hard disk drive with the positioning screw on the HDD tray 5 Secure the hard disk drive with five screws 6 Reinsert the HDD tray into the slot and close the locking lever 4 5 Press Pull 2 3 1 ...

Страница 40: ...he motherboard with a single screw 5 Reverse steps 1 4 to remove the M 2 device 1 2 3 4 WARNING Installation of the thermal pad over the M 2 device is required when installing an M 2 device Lack of the thermal pad may result in system overheat and throttle the system performance CAUTION The position of the stand off screw will depend on the size of the M 2 device The stand off screw is pre install...

Страница 41: ...e a fan assembly 1 Flip the latches on the top of the fan outwards 2 Using the latches lift up the fan assembly from the chassis 3 Reverse the previous steps to install the replacement fan assembly 1 2 The image below shows the system image of R282 Z90 The same process applies to R282 Z91 and R282 Z90 ...

Страница 42: ...ght side of the power supply unit in the direction indicated 3 Pull out the power supply unit using the handle 4 Insert the replacement power supply unit firmly into the chassis Connect the AC power cord to the replacement power supply 5 Repeat steps 1 4 for replacement of the second power supply 3 1 2 4 Before you remove or install the power supply unit Make sure the system is not turned on or co...

Страница 43: ...System Hardware Installation 43 Onboard SATA Onboard SATA 3 12 Cable Routing ...

Страница 44: ... 44 System Hardware Installation HDD Backplane Board Power HDD Backplane Board Signal ...

Страница 45: ... 45 System Hardware Installation Front Panel USB 3 0 Ports Front Panel LEDs and Buttons ...

Страница 46: ...System Hardware Installation 46 GPU Card Power ...

Страница 47: ...1 22 23 24 25 15 16 17 Item Description 1 Front Panel USB 3 0 Connector 2 Front Panel Connector 3 2 x 4 Pin P12V GPU Power Connector 4 2 x 4 Pin P12V GPU Power Connector 5 IPMB Connector 6 Serial Port Cable Connector 7 OCP Mezzanine Connector OCP 3 0 SFF Type Gen4 x16 8 BMC Firmware Readiness LED 9 TPM Module Connector SPI Interface ...

Страница 48: ...onnector 16 2 x 3 Pin Rear Back Plane Board Power Connector 17 OCP Mezzanine Connector OCP 2 0 Gen3 x8 18 Riser Connector 2 PCIe Gen4 x32 Slot 19 Riser Connector 3 PCIe Gen4 x16 Slot 20 Power Supply Connector 1 Primary 21 Power Supply Connector 2 Secondary 22 SlimLine SAS Connector SLSAS_2 PCIe SATA Defined by SKUs 23 SlimLine SAS Connector SLSAS_3 PCIe SATA Defined by SKUs 24 2 x 7 Pin HDD Back P...

Страница 49: ...de Normal Default BIOS Defined BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL PMBUS_SEL BIOS_PWD BIOS_RCVR Normal Default J2 1 2 3 4 Clear CMOS CLR_CMOS Enable Default 1 2 3 NCSI Switch 21 Onboard LAN OCP 2 0 Mezzanine OCP 3 0 Mezzanine SW1 OFF SW2 OFF ON ON OFF ON ...

Страница 50: ...Motherboard Components 50 This page intentionally left blank ...

Страница 51: ... caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this chapter ...

Страница 52: ...k main chipset and system event logs Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make...

Страница 53: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 54: ...on number of the BIOS setup utility BIOS Information Project Name Displays the project name information Project Version Displays version number of the BIOS setup utility Build Date and Time Displays the date and time when the BIOS setup utility was created BMC Information BMC Firmware Version Displays version number of the BIOS setup utility Processor Information CPU 0 Brand String CPU 1 Brand Str...

Страница 55: ...ion information Onboard LAN Information LAN1 MAC Address Note2 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note1 The number of LAN ports listed will depend on the motherboard system model Note2 This secti...

Страница 56: ... Setup 56 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen ...

Страница 57: ...figuration Security Device Support Select Enable to activate TPM support feature Options available Enable Disable Default setting is Enable SPI TPM Support Options available Enabled Disabled Default setting is Enabled 5 2 1 Trusted Computing ...

Страница 58: ...BIOS Setup 58 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Страница 59: ... 59 BIOS Setup 5 2 3 Legacy Video Select Parameter Description OnBrd Ext VGA Select Select between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard ...

Страница 60: ...BIOS Setup 60 5 2 4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information ...

Страница 61: ...ngs Change Settings Note2 Select an optimal setting for the Super I O device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 ...

Страница 62: ...rom S5 Enable or disable system wake on alarm event Select Fixed Time system will wake on the time HH MM SS specified Select Dynamic Time and the system will wake at the current time plus an increase in minute s Options available Disabled Fixed Time Default setting is Disabled ...

Страница 63: ... the available COM ports Serial Port for Out of Band Management Windows Emergency Management Services EMS Console Redirection Note Selects a COM port for EMS console redirection EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled COM1 SOL COM2 Console Redirecti...

Страница 64: ...with slow devices may require more than 1 stop bit Options available 1 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal...

Страница 65: ...S Console Redirection Settings Out of Band Mgmt Port Selects a serial port to remotely manage a Windows server OS Options available COM1 SOL COM2 Default setting is COM1 SOL Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is VT UTF8 Bits per second Selects the transfer rate for console redirection Options available...

Страница 66: ...tions available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 Information Press Enter to view more information related to CPU 0 CPU 1 Information Press Enter to view more information related to CPU 1 ...

Страница 67: ... 67 BIOS Setup 5 2 8 PCI Subsystem Settings ...

Страница 68: ...sion ROM for the related PCI E slot Options available Enabled Disabled Default setting is Enabled Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devi...

Страница 69: ...ff Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support ...

Страница 70: ...er Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 HDisk0 1 00 Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media will be emulated according to ...

Страница 71: ... 71 BIOS Setup 5 2 10 NVMe Configuration Parameter Description NVMe controller and Drive Information Displays the NVMe devices connected to the system ...

Страница 72: ...BIOS Setup 72 5 2 11 SATA Configuration ...

Страница 73: ...lable Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Disabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled IPSEC Certificate Note Enable Disable the IPSEC Certificate feature PXE boot wait time Note Wait time in ...

Страница 74: ...anced items Channel A BC D E F G H DIMM0 Presence DIMM1 Presence Chipset Bank Interleave Dram EC Dram Parity Dimm Sensor Fine Grain Mode CPU 1 Press Enter for configuration of advanced items Channel I J K L M N O P DIMM0 Presence DIMM1 Presence Chipset Bank Interleave Dram EC Dram Parity Dimm Sensor Fine Grain Mode ...

Страница 75: ...Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add Attempt Press Enter for configuration of advanced items Delete Attempt Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Страница 76: ...n Press Enter for configuration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration N A ...

Страница 77: ... 77 BIOS Setup 5 2 16 Intel R I350 Gigabit Network Connection ...

Страница 78: ... Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Controller PCI D...

Страница 79: ... 79 BIOS Setup 5 2 17 VLAN Configuration ...

Страница 80: ...m 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Enable Disable the VLAN Options available Enable Disable Default setting is Disabled Remove VLAN Press Enter to remove an existing VLAN Note Onl...

Страница 81: ...e Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter and then choose to save or discard the changes made Note This item will ap...

Страница 82: ... Table Gateway addresses DNS addresses Interface ID The 64 bit alternative interface ID for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor Solicitaion messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Addres Detection is not performed Policy Save Changes...

Страница 83: ...etup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Страница 84: ...ber of CCDs to be used the number of cores to be used and whether to enable or disable symmetric multithreading Prefetcher settings Press Enter for more options L1 Stream HW Prefetcher Option to enable or disable L1 Stream HW Prefetcher Options available Disable Enable Auto Default option is Auto L2 Stream HW Prefetcher Option to enable or disable L2 Stream HW Prefetcher Options available Disable ...

Страница 85: ...ount This field specifies the max valid ASID which affects the maximum system physical address space 16TB of physical address space is available for systems that support 253 ASIDs while 8TB of physical address space is available for systems that support 509 ASIDs Options available 253 ASIDs 509 ASIDs Auto Default option is Auto SEV ES ASID Space Limit Control Space limit control for SEV ES ASIDs O...

Страница 86: ...s expected breakpoint redirect capability compromised Silver workaround DbReq PDM and breakpoint redirect function as expected SCAN capability compromised Options available Auto No Workaround Bronze Workaround Silver Workaround Default option is Auto PPIN Opt in Turns on PPIN feature Options available Disabled Enabled Auto Default option is Auto ...

Страница 87: ...s 48 hours Auto Default option is Auto Poison scrubber control Allows you to enable or disable poison scrubber control Options available Disabled Enabled Auto Default option is Auto Redirect scrubber control Allows you to enable or disable redirect of scrubber control Options available Disabled Enabled Auto Default option is Auto Redirect scrubber limit Allows you to set the redirect scrubber limi...

Страница 88: ... to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Do not remap Attempt to remap Auto Default option is Auto DRAM map inversion Inverting the map will cause the highest memory channels to get assigned the lowest addresses in the system Options available Disabl...

Страница 89: ... UMC downstream slaves Options avaialble Sync flood disabled Sync flood enabled Auto Default option is Auto Disable DF sync flood propagation Enable Disable DF SyncFlood Options avaialble Sync flood disabled Sync flood enabled Auto Default option is Auto Freeze DF module queues on error Controls DF PIE Config Disabling this options sets DF PIEConfig Options available Disable Enable Auto Default op...

Страница 90: ...bles enforcement of POR restrictions for DDR4 frequency and voltage programming DRAM Controller Configuration Press Enter to configure DRAM controller options CAD Bus Configuration Press Enter to configure CAD Bus options Data Bus configuration Press Enter to configure Data Bus options Common RAS Press Enter to configure Common RAS options Security Press Enter to configure UMC security options ...

Страница 91: ...tion is Auto Address Hash Bank Enable or disable bank address hashing Options available Disabled Enabled Auto Default option is Auto Address Hash CS Enable or disable CS address hashing Options available Auto Enabled Disabled Default option is Auto Address Hash Rm Enable or disable RM address hashing Options available Auto Enabled Disabled Default option is Auto SPD Read Optimization Enable or dis...

Страница 92: ...s available Enable Disabled Auto Default option is Auto PCIe ARI Support Enables Alternative Routing ID Interpretation Options available Disable Enable Auto Default option is Auto PCIe Ten Bit Tag Support Enables PCIe ten bit tags for supported devices Auto Disabled Options available Disable Enable Auto Default option is Auto HD Audio Enable Enables or disables HD Audio Options available Enable Di...

Страница 93: ...power efficiency optimized CCLK DPM settings Options available Auto Enabled Default option is Auto Package Power Limit Control Auto Use the fused PPT Manual User can set PPT PPT will be used as the ASIC power limit Options available Manual Auto Default option is Manual xGMI Link Width Control Auto Use degault xGMI link width controller Manual User can set custom xGMI link width controller settings...

Страница 94: ... to APML When set to FALSE that reporting will be disabled Options available Enabled Disabled Default option is Disabled Egress Poison Mask High Enter a value These set the enable mask for masking of errors logged in EGRESS_POISON_STATUS For each bit set to 1 errors are masked For each bit set to 0 errors trigger response actions Egress Poison Mask Low Enter a value These set the enable mask for m...

Страница 95: ...erted to Okay responses Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default option is Log Errors in MCA Log Poison Data from SLINK This value specifies whether poison data propogated from SLINK will generate a deferred error When this value is set to TRUE deferred errors are enabled When set to FALSE errors are not generated Options available Enabled Disabled Default option i...

Страница 96: ...ble AER Cap Enables Advanced Error Reporting Capabilty Options available Enable Disabled Auto Default option is Auto Early Link Speed Sets Early Link Speed Options available Auto Gen1 Gen2 Default option is Auto Hot Plug Handling mode Controls the Hot Plug Handling mode Options available A0 Mode OS First No Error Handling OS First Error Handling Not Implementd Firmware First Not Implemented Auto D...

Страница 97: ...e or disable SATA RAS support Options available Disabled Enabled Auto Default setting is Auto Sata Disabled AHCI Prefetch Function Enable or disable Sata Disabled AHCI Prefetch Function Options available Disabled Enabled Auto Default setting is Auto Aggressive SATA Device Sleep Port 0 Options available Disabled Enabled Auto Default setting is Auto Aggressive SATA Device Sleep Port 1 Options availa...

Страница 98: ...ss Control Select AC Loss Control Method Options available Power Off Power On Last State Default setting is Last State I2C Configuration Options Press Enter for more options I2C 0 1 2 3 4 5 Enable Enable or disable I2C 0 1 2 3 4 5 Options available Disabled Enabled Auto Default setting is Auto Uart Configuration Options Press Enter for more options Uart 0 Enable Uart 0 has no HW FC if Uart 2 is en...

Страница 99: ...ll select MS driver for SD selections Options available AMD eMMC Driver MS Driver Auto Default setting is Auto D3 Cold Support Options available Disabled Enabled Auto Default setting is Auto eMMC Boot Options available Disabled Enabled Auto Default setting is Auto FCH RAS Options Press Enter for more options ALink RAS Support Options available Disabled Enabled Auto Default setting is Auto Reset af...

Страница 100: ...BIOS Setup 100 5 3 6 NTB Common Options Parameter Description NTB Common Options NTB Enable Enable or disable OnChip SATA controller Options available Auto Enable Default setting is Auto ...

Страница 101: ...l Parameter Description Soc Miscellaneous Control ABL Console Out Control Enable Enable ConsoleOut Function for ABL Disable Disable ConsoleOut Function for ABL Auto Keep default behavior Options available Disable Enable Auto Default setting is Auto ...

Страница 102: ...g the function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description AMD PBS RAS Press Enter for advanced configurations SPI Locking Enable or disable SPI Locking for protect ROM part Options Available Enabled Disabled Default option is Disabled ...

Страница 103: ...ue is 1000 dec SMI Scale Unit Defines the unit of time scale Options available millisecond second minute Default option is millisecond SMI Period Enter a value Defines the polling interval in milliseconds Default option is 1000 dec Maximum value is 32767 dec 0 disable GHES Notify Type Notification type for deferred corrected errors Options Available Polled SCI Default option is Polled GHES UnCorr ...

Страница 104: ...Device UnCorr Err Mask Reg Enter a value Intialize the PCIe AER Uncorrected Error Mask register of PCIe Device PCIe Device UnCorr Error Sev Reg Enter a value Intialize the PCIe AER Uncorrected Error Severity registers of PCIe Device CCIX GHES Deferred Err Notify Type Notification type for CCIX deferred errors Options Available Polled SCI Default option is Polled CCIX GHES Corrected Err Notify Type...

Страница 105: ...reen Parameter Description PCIe Link Training Type PCIe Link training in 1 or 2 steps Options available 1 Step 2Step Default setting is 1 Step PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enables or disables program all VR on MB Options available Disabled Enabled Default setting is Enabled North Bridge Press Enter for more information on the North Bridge ...

Страница 106: ...Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configure OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes NOTE This item is configurable when OS Watchdog Timer is set to Enabled OS Wtd Timer Policy Configure OS Watchdog Timer Policy Options available Rese...

Страница 107: ...Parameter Description View FRU Information Press Enter to view the advanced items BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Страница 108: ...sing SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options avail...

Страница 109: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Страница 110: ...BMC network parameters during BIOS phase Options available Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time synchronize BMC network parameter values Press En...

Страница 111: ...C network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IPv6 ...

Страница 112: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Страница 113: ...es being loaded before Windows loads and gets to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options available Standard Custom Default setting is Custom Restore Factory Keys Forces the system to...

Страница 114: ...splays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set Update Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set Update Append Forbidden Signature...

Страница 115: ...put the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Disabled Enabled Default setting is Enabled Boot mode select Selects the boot mode Options available LEGACY UEFI Default setting is UEFI FIXED BOOT ORDER Priorities Boot Option 1 2 3 4 5 Press ...

Страница 116: ...BIOS Setup 116 Parameter Description UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Страница 117: ...orities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 118: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 119: ... so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options available ...

Страница 120: ...PL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource ...

Отзывы: