SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0178
User Action:
Information only; no action is required
•
FQXSPSD0008L: Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
1. Replace any drive that is indicated by a lit status LED.
2. Re-create the array.
3. Restore the data from a backup.
•
FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Drive has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0163
User Action:
Information only; no action is required.
•
FQXSPSD2001I: The [StorageVolumeElementName] has been enabled.
This message is for the use case when an implementation has detected a Drive was Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0167
User Action:
Information only; no action is required.
•
FQXSPSD2002I: Failure no longer Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is no longer
Predicted.
.
141
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......