Use Storcli or LSA to check if there is any warning or critical RAID event.
•
FQXSPEA2002I: Sensor [SensorElementName] has transitioned to a less severe state from critical.
This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0523
User Action:
Use Storcli or LSA to check if there is any warning or critical RAID event.
•
FQXSPEM4000I: The [arg1] on system [arg2] cleared by user [arg3].
This message is for the use case where a Management Controller Event Log on a system is cleared by a
user.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0020
User Action:
Information only; no action is required.
•
FQXSPEM4001I: The [arg1] on system [arg2] is 75% full.
This message is for the use case where a Management Controller Event Log on a system is 75% full.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Event Log Fullness
SNMP Trap ID: 35
CIM Prefix: IMM CIM ID: 0037
User Action:
Information only; no action is required.
•
FQXSPEM4002I: The [arg1] on system [arg2] is 100% full.
This message is for the use case where a Management Controller Event Log on a system is 100% full.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Event Log Fullness
SNMP Trap ID: 35
CIM Prefix: IMM CIM ID: 0038
User Action:
To avoid losing older log entries, save the log as a text file and clear the log.
74
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......