Configure new power capping setting to indicated compute node through web GUI or OEM IPMI
command.
•
21070136: Node 3 Power Cap: Slot Or Connector, transition to Non-Critical from OK was asserted.
The power capping setting restored to indicated compute node is lower than the boundary of its inventory
power.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 554107190
User Action:
Configure new power capping setting to indicated compute node through web GUI or OEM IPMI
command.
•
21070137: Node 4 Power Cap: Slot Or Connector, transition to Non-Critical from OK was asserted.
The power capping setting restored to indicated compute node is lower than the boundary of its inventory
power.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 554107191
User Action:
Configure new power capping setting to indicated compute node through web GUI or OEM IPMI
command.
•
21070140: Node 1 Pwr Perm: Slot Or Connector, transition to Non-Critical from OK was asserted.
The indicated compute node hasn't acquired power permission to into ready state.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 554107200
User Action:
1. Please check the enclosure event refer to following section
– For DW612 enclosure
– If the Shared IO mode is enabled, the auxiliary node will acquire power permisson once the
primary node is power on.
– For DA240 enclosure
– Ensure all fan modules are well installed and have no fault event.
2. If the event persists, reseat the indicated compute node if the node is under power fault condition.
(Service technician only)
3. If the event persists, reset the BMC on indicated compute node.
4. If the event persists, ensure the indicated compute node is completely power off and then reseat it.
(Service technician only)
5. If the event persists, replace the indicated compute node. (Service technician only)
6. If the event persists, please consult with technical service.
•
21070141: Node 2 Pwr Perm: Slot Or Connector, transition to Non-Critical from OK was asserted.
The indicated compute node hasn't acquired power permission to into ready state.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 554107201
User Action:
36
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......