0401007B: Fan 2 Tach A: Fan sensor, warning event was asserted, reading value %RPM (Threshold
%RPM)
Asserted when fan tach reading is below warning threshold in RPM.
Severity: Warning
Alert Category: Thermal - System Thermal event
SNMP Trap ID: 67174523
User Action:
1. Ensure the indicated fan module properly installed.
2. If the event persists, reseat the indicated fan module. (Service technician only)
3. If the event persists, replace the indicated fan module. (Service technician only)
4. If the event persists, please consult with technical service.
•
0401007C: Fan 2 Tach B: Fan sensor, warning event was asserted, reading value %RPM (Threshold
%RPM)
Asserted when fan tach reading is below warning threshold in RPM.
Severity: Warning
Alert Category: Thermal - System Thermal event
SNMP Trap ID: 67174524
User Action:
1. Ensure the indicated fan module properly installed.
2. If the event persists, reseat the indicated fan module. (Service technician only)
3. If the event persists, replace the indicated fan module. (Service technician only)
4. If the event persists, please consult with technical service.
•
0401007D: Fan 3 Tach A: Fan sensor, warning event was asserted, reading value %RPM (Threshold
%RPM)
Asserted when fan tach reading is below warning threshold in RPM.
Severity: Warning
Alert Category: Thermal - System Thermal event
SNMP Trap ID: 67174525
User Action:
1. Ensure the indicated fan module properly installed.
2. If the event persists, reseat the indicated fan module. (Service technician only)
3. If the event persists, replace the indicated fan module. (Service technician only)
4. If the event persists, please consult with technical service.
•
0401007E: Fan 3 Tach B: Fan sensor, warning event was asserted, reading value %RPM (Threshold
%RPM)
Asserted when fan tach reading is below warning threshold in RPM.
Severity: Warning
Alert Category: Thermal - System Thermal event
SNMP Trap ID: 67174526
User Action:
1. Ensure the indicated fan module properly installed.
2. If the event persists, reseat the indicated fan module. (Service technician only)
.
19
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......