User Action:
Information only; no action is required
•
FQXSPPW2002I: [PowerSupplyElementName] has returned to OK status.
This message is for the use case when an implementation has detected a Power Supply return to normal
operational status.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0087
User Action:
Information only; no action is required
•
FQXSPPW2003I: Failure no longer predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is no
longer predicted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0089
User Action:
Information only; no action is required
•
FQXSPPW2005I: [PowerSupplyElementName] has returned to a Normal Input State.
This message is for the use case when an implementation has detected a Power Supply that has input
that has returned to normal.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0099
User Action:
Information only; no action is required
•
FQXSPPW2006I: [PowerSupplyElementName] has returned to a Normal Input State.
This message is for the use case when an implementation has detected a Power Supply that has input
that has returned to normal.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0099
134
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......