Complete the following steps:
1. Power off the system.
2. Reconfig the Intel Optane PMEM.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFMA0046M: DIMM [arg1] is disabled because it is Intel Optane PMEM that is not supported
on current platform
Severity: Error
User Action:
Complete the following steps:
1. Power off the system.
2. Remove the unsupported Intel Optane PMEM from this system.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFMA0047M: SPD CRC checking failed on DIMM [arg1]. [arg2]
Severity: Warning
User Action:
Complete the following steps:
1. Perform a virtual reseat or AC cycle the server.
2. If the problem returns Collect Service Data log.
3. Contact Lenovo Support.
•
FQXSFPU0001N: An unsupported processor has been detected.
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for a firmware update required for this processor and install that update, if
applicable.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
•
FQXSFPU0002N: An invalid processor type has been detected.
Severity: Error
User Action:
Complete the following steps:
1. Verify that the Processor is a valid option that is listed as a Server Proven device for this system. If a
non-supported processor is identified, remove that Processor or replace with a supported Processor.
2. Check Lenovo support site for a firmware update required for this Processor and install that update,
if applicable.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
.
197
Содержание 7D1J
Страница 4: ...ii ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 8: ...4 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 174: ...170 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 238: ...234 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 242: ...238 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 244: ...240 ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference ...
Страница 245: ......
Страница 246: ......