16: Command Reference
EMG™ Edge Management Gateway User Guide
353
Sets the lowest humidity pemitted for the port.
sensorsoft highhumidity <High Humidity %>
Sets the lowest humidity permitted for the port.
sensorsoft degrees <celsius|fahrenheit>
Enables or disables temperature settings as celcius or fahrenheit.
sensorsoft traps <enable|disable>
Enables or disables traps when specified conditions are met.
sensorsoft status
Displays the status of the port.
sensorsoft showall
Displays the status for all connected Sensorsoft devices and ignores the device port\nlist.
Note:
The Sensorsoft lowtemp and hightemp settings are given in the scale specified by
the degrees setting.
Description
Sends commands to (or control) a device connected to an EMG device port over the serial port.
Note:
Currently the only devices supported for this type of interaction are Sensorsoft
devices.
Device Port Commands
set deviceport port
Description
Sets the dialout password.
Syntax
set deviceport port <Device Port # or List or Name> <one or more device
port parameters>
Example:
set deviceport port 2-5,6,12,15-16 baud 2400
Parameters
actiondelay <Action Delay>
actionrestart <Restart Delay>
assertdtr <enable|disable>
auth <pap|chap>
banner <Banner Text>
baud <300-921600>
breakseq <1-10 Chars>
bytethreshold <# of Characters>