15: Application Examples
EMG™ Edge Management Gateway User Guide
312
Max number of files: 10
Max size of files: 2048
2. Change the serial settings to match the serial settings for the vt100 terminal - changes baud to
57600 and disables flow control:
[EMG]> set deviceport port 2 baud 57600 flowcontrol none
Device Port settings successfully updated.
3. Create a connection between the vt100 terminal connected to device port 2 and an outbound
telnet session to the server. (The IP address of the server is 192.168.1.1):
[EMG]> connect bidirection 2 telnet 192.168.1.1
Connection settings successfully updated.
4. At the VT100 terminal, hit <return> a couple of times. The Telnet prompt from the server
displays:
Trying 192.168.1.1...
Connected to 192.168.1.1.
Escape character is '^]'.
Sun OS 8.0
login:
At this point, a user can log in and interact with the Sun server at the VT100 terminal as if directly
connected to the server.