WireWorks
®
Panel System
Assembly Instructions
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
13
Return Panel Guidelines
Definition of Return: A panel or
combination of panels that has
one of its ends connected to a run
of panels while the other end is
unsupported.
• Cannot exceed a total length of 8’
• Cannot consist of more than two
panels
• Cannot support overhead storage
• Cannot support worksurfaces or
counter tops
Rules:
• Any return between 48” and 96”
in length requires enhanced
horizontals.
• Any return greater than 48”
requires enhanced horizontals
on both panels that make up the
return.
• Two enhanced horizontals are
required per panel, one at the top
and the other at the bottom.
54-96”
This combination of two panels is
wider than 48”, therefore both
panels require Enhanced
Horizontals
This single panel is wider than
48”, therefore requires Enhanced
Horizontals
This combination of two panels is
adjacent to a worksurface, but still
requires Enhanced Horizontals in
both panels
This combination of two panels
attaches the adjacent worksurfaces
to a panel with a worksurface
support bracket (WSB), but still
requires Enhanced Horizontals in
both panels
54-60”
54-96”
54-96”
24-30”
24”
Examples: Where needed