background image

26

WireWorks

®

 Panel System

Assembly Instructions

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

Power Pass-Through  

Installation (Continued)

WARNING: 

Assembly of all 

mechanical frame components 

must be completed before 

making any electrical 

connections. All electrically 

connected furnishings must also 

be mechanically connected.

12”-18” PPT Installation

1. Orient the PPT so the  

N

  

symbol is pointing up.

2. Connect the “plug end” of the 

PPT to one of the adjacent rigid 

wireways (Figure 38).

3. Connect the “socket end” of 

the PPT to the other adjacent 

rigid wireway using a horizontal 

jumper (Figure 38).

Using a 12” or 18” PPT

Note: 

If a 12” or 18” PPT is 

being used at a 90° intersection, 

the 20” jumper is used to turn 

the corner, not the PPT.

Содержание WireWorks

Страница 1: ...Assembly Instructions WireWorks Panel System January 2020...

Страница 2: ...A...

Страница 3: ...assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury Required Tools 2 Overview 3 Frame Assembly 4 Enhanced Horizontals Rails 10 Tile Hook Install...

Страница 4: ...r assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury Required Tools for Assembly The following tools are required to assemble panels Dead blow...

Страница 5: ...parts may result in assembly failure and personal injury 3 Scope of Manual This installation manual is organized in the same order as a typical installation would be conducted Starting with frame mem...

Страница 6: ...sult in assembly failure and personal injury Overview WireWorks Panel System uses four basic parts to build the framework for the panels full width vertical post half width vertical post horizontal ra...

Страница 7: ...sary intersection specifications 1 Assemble intersections by bolting two three or four half posts together using a connector block shoulder bolts and washers with a 3 16 allen wrench Figure 1 Refer to...

Страница 8: ...njury Assembling Intersections continued 2 Install height change connector block if required to the frame using shoulder bolts and washers with a 3 16 allen wrench Figure 2 Refer to the table on next...

Страница 9: ...fying the shortest panel in your intersection Refer to corresponding chart 3 Determine quantity of height change connector blocks by subtracting heights of the two shortest panels Refer to the chart f...

Страница 10: ...also use horizontals at intermediate heights with the opening facing up Note Refer to the space planning layout and start with a panel corner intersection building out in two directions so the panel f...

Страница 11: ...et of pockets on the vertical posts with the opening facing downward and tap into place with a dead blow style mallet Continue to add horizontals as required by the style of panel Figure 7 Note Rememb...

Страница 12: ...olts must be tightened securely and must be checked periodically after assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury Recognizing Enhanced...

Страница 13: ...more than one tile use additional standard construction horizontals at intermediate heights with the opening facing up Note Refer to the space planning layout to determine which panels receive enhance...

Страница 14: ...ls relative to the lowest set of embossed areas on the vertical posts with the opening downward and tap into place with a dead blow style mallet Continue to add standard horizontals as required by the...

Страница 15: ...pport worksurfaces or counter tops Rules Any return between 48 and 96 in length requires enhanced horizontals Any return greater than 48 requires enhanced horizontals on both panels that make up the r...

Страница 16: ...otate the hook one quarter turn to the right so the top of the hook is pointing upward Figure 14 Hint If the tile hook does not turn properly the horizontal has not been installed properly Check to be...

Страница 17: ...into the appropriate slot on the horizontal rail Slide the clips near side open saddles Figure 16 on to the frame until a snap is heard Then squeeze frame until the far side saddles engage the rail a...

Страница 18: ...l jumper Figure 19 Horizontal jumpers use a plastic mesh sheathing and come in two lengths 17 and 20 The 17 jumpers are used on inline conditions while 20 jumpers are used to pass straight through an...

Страница 19: ...mpers are used to run power within a single panel between two different heights There are two lengths of vertical jumpers 20 and 56 The 56 long vertical jumper is capable of running power from the bas...

Страница 20: ...zel filler plate into the unused bottom opening of the bezel from the inside Figure 20 Note The bezel filler plates always occupy the lower of the two openings on bezels in base raceways The bezel fil...

Страница 21: ...e a painted steel or fabric wrapped steel face 1 Determine the position at which the receptacle will be installed and ensure a rigid wireway is already mounted behind the raceway tile See page 15 2 Re...

Страница 22: ...first rotate the top hook into the opening in the base raceway then snap the bottom into position to secure Figure 29 Figure 26 Figure 27 Figure 28 Figure 29 base raceway door base raceway door base r...

Страница 23: ...ure and personal injury 21 Installing Base Trim at Intersections When base trim is snapped into place at 90 and T intersections the upper tabs engage slots in the half post and the lower tabs snap ove...

Страница 24: ...Installation 1 Install the base module receptacle portion of the non handed universal base infeed into the rigid wireway as shown Figure 31 Use the same procedure you use for installing a receptacle S...

Страница 25: ...y connected furnishings must also be mechanically connected Note The panel being used as the top infeed panel must be in its final position in the room The top infeed consists of four parts the power...

Страница 26: ...time 2 Insert a screw into the hole in each half of the trim The screw will go through the trim and into the boss on the opposite piece of trim Detail H 3 Tighten the screw until the two halves of tr...

Страница 27: ...have receptacles installed in them Note The 24 60 PPTs are the same length as a corresponding rigid wireway and have connection sockets on each end The 36 60 PPTs feature flexible steel conduit in the...

Страница 28: ...NING Assembly of all mechanical frame components must be completed before making any electrical connections All electrically connected furnishings must also be mechanically connected 12 18 PPT Install...

Страница 29: ...n the trough of the top horizontal rail For 90 intersections the optional 90 top cap cable guard can be slid in between half posts to enforce a 1 minimum bend radius around 90 corners Figure 39 2 Opti...

Страница 30: ...commended that wires only be run behind tiles which you will have easy access to after the installation is complete You will not be able to hang on module mounted components in front of areas where da...

Страница 31: ...scribed herein only To do otherwise may result in instability All screws nuts and bolts must be tightened securely and must be checked periodically after assembly Failure to assemble properly or to se...

Страница 32: ...horizontal cable support To install align the rectangular projection on the top of the wire support with the rectangular hole in the horizontal Push the wire support through the horizontal and rotate...

Страница 33: ...able trough behind a raceway tile If a rigid wireway is not used then two cable troughs can be utilized to allow a total of 48 0 20 diameter four pair UTP data cables behind the raceway tile 1 Hang th...

Страница 34: ...d The septum is slid up flush underneath the rigid wireway and held in place by the supplied self drilling and tapping screws Figure 46 2 Lay the cables in the raceway as required Figure 47 Using one...

Страница 35: ...htened securely and must be checked periodically after assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 33 Storing Extra Data Cables Inside O...

Страница 36: ...2 Hold the top of the tile against the frame and gently lift up on the bottom of the tile while pushing it in toward the frame to engage the bottom hooks Let the tile slide down into position while c...

Страница 37: ...or razor blade remove the fabric Detail L 2 Snap the receptacle data bezel into the knock out to cover the cut edge of the fabric Figure 52 Caution should still be used to avoid excessive fraying of t...

Страница 38: ...ooks are used per side instead of four The extra hooks are installed just above the lower two hooks and just below the upper two hooks 1 With the tile hooks already in place on the frame See Installin...

Страница 39: ...ult in assembly failure and personal injury 37 Installing Top Caps Top caps snap over the top horizontal rail and are the same width as the panel 1 Align the cap over the top horizontal rail and firml...

Страница 40: ...urpose of the cap is to fill in the gap between the end of the base raceway and the end of run trim 2 Install end of run top cap into the end of run trim A To Floor note is molded into the inside of t...

Страница 41: ...h downward and snap the trim over the exposed portions of the connector block Figure 62 Note Face the opening of all height change connector blocks toward the shortest panel to allow for lay in wire m...

Страница 42: ...lled over the exposed portion of a full post in an in line height change condition 1 Remove the lower top cap in the intersection and trim the required amount from its length Replace the trim Hint Use...

Страница 43: ...l by taking off any tile hooks that are locking the horizontal rail in place Then tap the horizontal rail out with a dead blow mallet Once the horizontal rail is free from the pockets on the vertical...

Страница 44: ...vertical post and the top trough cable guard if equipped 2 Position the stacking splice above the top of the vertical post and tap into place Do not damage top of stacking splice during installation...

Страница 45: ...f panels Panels may be stacked to a maximum height of 12 and must remain below the height of the ceiling but the returns must remain within 18 in height of the main run Any combination of glass open o...

Страница 46: ...44...

Страница 47: ...45...

Страница 48: ...e Street P O Box 8100 Green Bay Wisconsin 54308 8100 1 800 424 2432 www ki com KI is a registered trademark of Krueger International Inc 2020 Krueger International Inc All Rights Reserved Code KI 6083...