WireWorks
®
Panel System
Assembly Instructions
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
25
Installing Power Pass-Through
WARNING:
Assembly of all
mechanical frame components
must be completed before
making any electrical
connections. All electrically
connected furnishings must also
be mechanically connected.
Power Pass-Throughs (PPT) are
used in place of rigid wireways to
continue power through panels
that will never need to have
receptacles installed in them.
Note:
• The 24”-60” PPTs are the same
length as a corresponding rigid
wireway and have connection
sockets on each end.
• The 36”-60” PPTs feature flexible
steel conduit in the middle
section.
• The 24” and 30” PPTs feature
steel “clamshells” in the middle
section.
• The 12” and 18” PPTs feature
flexible steel conduit in the
middle with a connection socket
on one end and a connection
plug on the other end
(Figure 37).
• PPTs connect to adjacent
electrical components using
horizontal jumpers the same
way rigid wireways connect (see
page 16).
• PPTs do not physically attach to
the panel framework. They simply
rest in the base cover or the
horizontal member.
24”-60” PPT Installation
1. Orient the PPT so the
N
symbol is pointing up.
2. Connect the PPT to adjacent
rigid wireways or PPTs using
the appropriate horizontal
jumper and the usual connection
procedure.