Load management program
47 / 156
Metering
Publishes meter values:
Decides how intermediate meter reading will be handled.
Display values:
No:
Intermediate meter readings will neither be stored in the Charging
Transaction nor written to a log file.
Most recent:
The most recent intermediate meter reading will be stored at the
Charging Transaction, but no log file entry will be written.
Full log:
The most recent intermediate meter reading will be stored at the
Charging Transaction and written to the log file.
Metering period:
Duration in seconds between two consecutive intermediate meter read-
ings.
Meter collection type:
Type of collection of meter readings for export.
Display values:
ClockAligned:
Meter readings will be generated for Sockets or the Charge Point.
They will be collected in evenly spaced intervals starting from mid-
night.
Sampled:
Meter readings will be generated for Charging sessions. They will be
collected at the start and end of the Charging session as well as in
evenly spaced intervals starting from the start of the Charging ses-
sion.
Both:
Both clock-aligned and sampled Meter readings will be collected.
Collection interval clock
aligned:
Size (in seconds) of the clock-aligned data interval. This is the size of the
set of evenly spaced aggregation intervals per day, starting at 00:00:00
(midnight).
Collection interval session
aligned:
Interval (in seconds) between sampling of metering data, intended to be
exported. Sampling starts at the begin of the Charging session.