Load management program
41 / 156
Typical workflow: Viewing Charge Point details
►
Press the
Monitoring
button
in the toolbar. The Charge Point Monitoring screen appears.
►
If the general information is not sufficient, more details can be seen at other tabs of the screen.
They can be reached by pressing
[>]
or
[<]
at the toolbar or by clicking at the tab headers shown
at the content area of the screen.
The following information can be viewed and analyzed in addition to general information. Most of
this information might be of interest for troubleshooting.
Load Management:
Configuration options for load management (distribution of available energy to all vehicles that
have been plugged into Wallboxes belonging to the Charge Point).
Authorization:
Configuration options for the way users will be authorized.
Metering and Power Control:
Configuration options for the process of controlling whether the electric vehicle doesn't use more
than the assigned power and for the way metering data will be collected.
Power Profile:
The currently active power profile determining limits of the available power over time.
Session overview:
This screen provides an overview of Charging Sessions that are ongoing or have been finished.
By selecting a Charging Session and pressing the "Session History" button, the session history
screen is shown for that particular session.
Session history:
A charging session starts, when an electric vehicle plugs in and stops when the electric vehicle
will be disconnected. During a Charging Session, there will be multiple charging transactions.
This screen provides an overview about the events that occurred during the processing of a
Charging Transaction.
Power Usage:
This screen shows how much energy has been consumed today or during a particular day in the
past.
►
Because most data shown at the screens are static, the screens will not be refreshed.
Up to date information can be loaded by clicking on the
Refresh
button
.
►
Return to the home screen by clicking on the
[HOME]
button
.