Load management program
69 / 156
General information
Charge Point operating
mode:
Describes whether the Charge Point allows Mode 3 charging controlled
by basic signalling, charging controlled by high-level communication or
both.
Values:
Only basic signalling (Mode 3 only)
:
Only Mode 3 charging controlled by basic signalling according to
IEC 61851-1 is possible.
Only ISO 15118
:
Only vehicles using high-level communication can be charged.
Combined mode
:
Both Mode 3 charging and charging with high-level communication is
supported.
[default value: Combined mode]
Maximum current Charge
Point:
Maximum available current (in Ampere) that is available at the Charge
Point. Most likely, this is a limitation determined by the power delivery
contract of the organization using the M10 system.
A new power profile will be created upon first entry of “Max. Available
Current” or if this value is changed by using this screen.
If this screen is used to change the “Max. Available Current” and there
are future-dated power profiles that offer more cur
rent than “Max. Availa-
ble Current”, those power profiles will be set to "Error" and can no longer
be used until they have been cor
rected. The state might change if “Max.
Available Current” is increased again or if the power profile is changed.
[Max. Available Current shall be between 16A and 480A (=15x32A)]
Nominal voltage:
Voltage (in Volt) used for calculations of power. Refers to a single phase
(e.g. 230V in continental Europe).
Valid single line nominal voltage values are:
110, 115, 120 (USA), 127, 208, 220, 230 (Europe), 240
Internet access?
[only ISO 15118 relevant]
Indicates whether internet access is possible for the Electric Vehicle at
the Charge Point.
[default value: disabled]
User interface
Measurement system:
Selection of the measurement system. Internally, the Load management
program uses the metric system. If the user selects the US system, any
conversion happens at the user interface.
Values:
Metric
:
Metric measurement system (meter, degree Celsius,…).
US
:
US measurement syste
m (yard, degree Fahrenheit,…).
[default value: Metric]