Load management program
66 / 156
6.6 Configuration menu
Press the
[Configuration]
button to show the “Configuration menu”.
Configuration screens for the Charge Point (global parameters).
Configuration menu
– Charge Point configuration
Additional information:
Operating mode
Cables connecting an electric vehicle with a KeContact P20 Wallbox contain 3 or 5 wires for the transport of
electric energy and two wires for data communication. There are two protocols (set of rules for communica-
tion) for data exchange between the electric vehicle and the Charge Point - Basic Signalling (according to
IEC 61851-1) and ISO/IEC 15118 (in short ISO 15118).
Those two protocols are not mutually exclusive, ISO 15118 works on top of Basic Signalling. ISO 15118 is
better suited to optimize the power delivery capacity of the electricity grid and can handle authorization. As of
today, most electric vehicles only support basic signalling.