Load management program
78 / 156
Typical workflow: Configure power control
►
Press the
[Configuration]
button
in the toolbar at the bottom of the screen. The charge
point configuration screen appears.
►
Select the tab
“Metering and Power Control”
.
►
Update the power control settings and press the
[Save]
button.
►
Return to the home screen by clicking on the
[HOME]
button
.
Typical workflow: Manage power control
►
An electric vehicle has been blocked because of power control.
Use the monitoring screens to analyze the situation (see “Monitor Charging sessions”).
►
If the electric vehicle has been blocked because of an incorrect configuration, correct the power
control settings (refer to workflow “Configure Power Control”).
►
Depending on the results of the analysis, unblock the charging session.
If a vehicle is unblocked that has been blocked by power control, Power control might block the
electric vehicle again if it still doesn’t follow the rules. Unblocking therefore only make sense in
case of a temporary violation or after the settings for power control have been modified.
►
Return to the home screen by clicking on the
[HOME]
button
.