Load management program
73 / 156
6.6.1.3
Authorization tab
Charge Point configuration
– Authorization
Charge Point information
ID:
Unique ID of the Charge Point. In ISO 15118-2, the ID of the Charge
Point is called EVSE-ID. According to ISO 15118-2, it is a globally unique
identifier containing an octet string. In communication with the Electric
Vehicle, the Charge Point ID will be concatenated with the Socket ID to
receive the EVSE-ID.
[default value: Charge Point ID]
Name:
Human-readable name of the Charge Point for presentation purposes.
[default value: Charge Point ID]
Authorization [only ISO 15118 relevant]*
Authorization enabled?
Decides whether authorization is enabled at the Charge Point.
If the attribute Authorizing Charge Point is disabled, all sockets will be set
to non-authorizing.
Learns charging token?
Decides whether a Charging Token can be generated, if an Electric Vehi-
cle plugs into a Socket with disabled Authorization.
Note.
A creation of Charging Tokens will only be done for some types of
Charging Tokens such as PEV-IDs.