Load management program
94 / 156
Parameters
ID:
Unique ID of the Charge Point. In ISO 15118-2, the ID of the Charge
Point is called EVSE-ID. According to ISO 15118-2, it is a globally unique
identifier containing an octet string. In communication with the Electric
Vehicle, the Charge Point ID will be concatenated with the Socket ID to
receive the EVSE-ID.
[default value: Charge Point ID]
Name:
Human-readable name of the Charge Point for presentation purposes.
[default value: Charge Point ID]
Charge point Operator:
Human-readable name of the operator of the Charge Point.
[default value: empty]
Nominal Voltage:
Voltage (in Volt) used for calculations of power. Refers to a single phase
(e.g. 230V in continental Europe).
Valid single line nominal voltage values are:
110, 115, 120 (USA), 127, 208, 220, 230 (Europe), 240
Maximum current Charge
point:
Maximum available current (in Ampere) that is available at the Charge
Point. Most likely, this is a limitation determined by the power delivery
contract of the organization using the M10 system.
A new power profile will be created upon first entry of “Max. Available
Current” or if this value is changed by using this screen.
If the install screen is used to chan
ge the “Max. Available Current” and
there are future-dated power profiles that offers more cur
rent than “Max.
Available Current”, those power profiles will be set to "Error" and can no
longer be used until they have been corrected. The state might change if
“Max. Available Current” is increased again or if the power profile is
changed.
[Max. Available Current shall be between 16A and 480A (=15x32A)]
Charge Point operating
mode:
Describes whether the Charge Point allows Mode 3 charging controlled
by basic signalling, charging controlled by high-level communication or
both.
Values:
Only basic signalling (Mode 3 only)
:
Only Mode 3 charging controlled by basic signalling according to
IEC 61851-1 is possible.
Only ISO 15118
:
Only vehicles using high-level communication can be charged.
Combined mode
:
Both Mode 3 charging and charging with high-level communication is
supported.
[default value: Combined mode]
Authorization enabled?
Indicates whether authorization is enabled at the Charge Point.
[default value: disabled]