Load management program
115 / 156
White list
White list version:
Version number of the white list.
- The white list version entered into this text field and the white list version
in the database must match.
Update type:
Indicates how the white list file will be applied.
Display Values:
Full:
Charging tokens in the database that are not contained in the import
file will be deleted (Replace IDs entered at the GUI=disabled re-
quired).
Partial:
Charging tokens in the database are not deleted when importing of a
new white list file.
Imported only
Only the charging tokens in the import file will be synchronized with
the whitelist tokens that have been imported previously. The charging
tokens entered at the GUI will not be considered.
Replace IDs entered at the
GUI?
Charging tokens in the import file that are already contained in the data-
base will be overwritten (checkbox enabled), otherwise ignored.
Buttons
Import:
Press the [Import] button to select a file for upload.
- Charging tokens in the import file that are not yet contained in the data-
base will be imported.
- The import doesn't affect charging tokens with the Token
Type="Manual", they will neither be overwritten nor deleted.
- If the white list version in the import file has already been imported, the
import will be rejected.
- The charging tokens inside the file must have a valid Token Type. To-
ken Type "Manual" is not allowed.
Typical workflow: Import White list items
►
Press the
[Management]
button
in the toolbar. The Management screen (Charging Session
Management) appears.
►
Click at the button
[White list]
in the menu bar. The white list management screen appears.
►
Press the
[Import]
button. The white list import screens appears.
►
Enter the parameters required for the upload and press the
[Import]
button.
A dialogue box appears that allows the selection of a file for upload to the KeContact M10.
►
Return to the home screen by clicking on the
[HOME]
button
.