Load management program
91 / 156
6.6.5 View Power Profile
Configuration menu - View Power Profile
Power profile
Valid from:
Point in time at which the validity of a Power Profile begins. A Power Pro-
file remains valid until its successor gets valid.
Special day:
Special day at which the Power Profile overrides the currently active
Power Profile.
Reserved for ISO 15118:
Percentage of the Maximum Current Offered that is reserved for Electric
Vehicles using high-level communication.
Maximum current Charge
Point:
Max available current (in Ampere) that is available at the Charge Point.
Most likely, this is a limitation determined by the power delivery contract
of the organization using the M10 system.
Power profile entries
Days of week:
Days at which the Power Profile is valid.
From / To:
Time period from / to the Power Profile is valid.
Max. Current:
Maximum current for this Power Profile.
Price:
Energy price during this Power Profile.
Current ISO 15118:
Current (in Ampere) that is reserved for charging by vehicles using high-
level communication.