First time installation
28 / 156
Nominal Voltage:
Voltage (in Volt) used for calculations of power. Refers to a single phase
(e.g. 230V in continental Europe).
Valid single line nominal voltage values are:
110, 115, 120 (USA), 127, 208, 220, 230 (Europe), 240
Maximum current Charge
point:
Maximum available current (in Ampere) that is available at the Charge
Point.
A new power profile will be created upon first entry of “Max. Available
Current” or if this value is changed.
If the install screen is used to change the “Max. Available Current” and
there are future-dated power profiles that offers more cur
rent than “Max.
Available Current”, those power profiles will be set to "Error" and can no
longer be used until they have been corrected.
[Max. Available Current shall be between 16A and 480A (=15x32A)]
Charge Point operating
mode:
Describes whether the Charge Point allows Mode 3 charging controlled
by basic signalling, charging controlled by high-level communication or
both.
Values:
Only basic signalling (Mode 3 only)
:
Only Mode 3 charging controlled by basic signalling according to
IEC 61851-1 is possible.
Only ISO 15118
:
Only vehicles using high-level communication can be charged.
Combined mode
:
Both Mode 3 charging and charging with high-level communication is
supported.
[default value: Combined mode]
Authorization enabled?
Indicates whether authorization is enabled at the Charge Point.
[default value: disabled]
Internet access?
Indicates whether internet access is possible for the Electric Vehicle at
the Charge Point.
[default value: disabled]
Measurement system:
Selection of the measurement system. Internally, the Load management
program uses the metric system. If the user selects the US system, any
conversion happens at the user interface.
Values:
Metric
:
Metric measurement system (meter, degree Celsius,
…).
US
:
US measurement system (yard, degree Fahrenheit,…).
[default value: Metric]