74
English
Malfunctions during dry foam production (option)
Malfunctions in the water treatment
Malfunction
Possible cause
Rectification
By whom
Foam quality is poor,
foam too dry or too wet
Detergent container empty
Replace the container.
Operator
Suction filter dosing pump is clogged Rinse the filter with warm water.
Operator
Water supply is too low
Restore the water supply, check the setting of the foam station pressure reducer
(0.25 MPa (2.5 bar)).
Operator
Compressor does not supply air
Check the compressor. Drain the condensation water from the compressor pres-
sure tank.
Customer Service
Compressor is overheated
After cooling down, the compressor automatically starts up again.
Operator
Pressure reducer of foam station is
contaminated
Clean the pressure reducer.
Operator
Solenoid valve for water/chemistry
does not open
Check voltage with a magnetic field tester, clean the solenoid valve, replace if nec-
essary
Operator, Customer
Service
The setting of the dosing valves for wa-
ter/chemistry or air is incorrect
Set to the standard setting (see chapter Operation and settings).
Customer Service
Incorrect detergent, detergent contam-
inated or old
Change the detergent.
Operator
Malfunction
Possible cause
Rectification
By whom
Base exchanger does not
regenerate
No power supply.
Check the power supply (fuse, plug, switch).
Operator, Customer
Service
Hardness sensor is defective
Check the hardness sensor, replace if necessary.
Customer Service
Base exchanger regener-
ates during operating time
Clock was adjusted by power failure
(option, only with WAT-S 202)
Reset the time (see "Settings/Setting the WAT-S 202 base autoexchanger")
Operator
Water remains hard after
regeneration
Salt tank is empty.
Refill softening salt, wait for brine formation (approx. 2 hours), start a manual re-
generation. Never allow the salt level to fall below the water level in the salt tank.
Operator
Injector filter is clogged
Clean the injector filter.
Customer Service
Water inflow to the salt tank is insuffi-
cient
Check the brine filling time, clean the brine filling orifice if necessary.
Customer Service
Riser pipe is leaking
Check the riser pipe and the pilot pipe.
Customer Service
Salt consumption is too
high
Too much water in the salt tank
Check the salt consumption and salt quantity setting.
Customer Service
Incorrect salt quantity setting
Pressure loss
Deposits in the water supply
Clean the water supply.
Customer Service
Deposits in the base exchanger
Clean the valve and resin board.
Customer Service
Too much water in the salt
tank
Rinsing screen is blocked
Clean the rinsing screen.
Customer Service
Injector is clogged
Clean the injector and filter.
Customer Service
Foreign body in the brine valve
Clean the brine valve, change the valve seat.
Customer Service
Power failure during brine filling
Check the power supply.
Customer Service
Brine is not sucked in
Water inlet pressure too low.
Increase the water inlet pressure to at least 0.3 MPa (3 bar).
Operator
Rinsing screen is blocked
Clean the rinsing screen.
Customer Service
Injector is clogged
Clean the injector and filter.
Customer Service
Leak in the valve interior
Replace the valve flaps.
Customer Service
Water is constantly in the
drain, even after regener-
ation
Valve does not perform cycles correct-
ly
Check the timer programme, replace the valve control if necessary.
Customer Service
Foreign body in the valve
Remove the valve control, remove the foreign body, check the valve in all posi-
tions.
Customer Service
RO pump does not start Permeate buffer tank is full
Wait until permeate is used up.
Operator
The “buffer tank full” level switch is
faulty
Check the level switch.
Customer Service
Start-up time of the controller is not yet
finished
Wait.
Operator
Pressure switch for water shortage
was triggered
Fine filter or active carbon filter is contaminated. Check both filters, replace the fil-
ter inlay if necessary.
Operator
Pressure switch has a water shortage
fault
Check the pressure switch, replace if necessary.
Customer Service
Base exchanger regeneration is run-
ning
Wait for the end of the regeneration.
Operator
No softened water comes from the
base exchanger
Check the base exchanger.
Operator, Customer
Service
Pump disconnection from mains (op-
tional) not working
Check the voltage supply. Check the pump.
Customer Service
RO pump only starts after
several flushing cycles
Water mains pressure too low
Check the water mains pressure, if necessary open the supply valve completely. Operator
Fine filter or active carbon filter is con-
taminated
Check both filters, replace the filter inlay if necessary.
Operator
Permeate output is too
low, buffer tank permeate
is often empty
Water supply temperature is too low
Measure the temperature of the softened water and compare it with the technical
data.
Operator
Operating pressure is too low
Readjust the operating pressure.
Customer Service
Lime or mineral deposits on the filter
surface of the RO membrane
Descale the membrane, replace if necessary.
Customer Service
The buffer tank “full” level switch is
faulty
Check the level switch.
Customer Service
Bacteria or algae deposits on the filter
surface of the RO membrane
Rinse the membrane for a long time, replace if necessary. Note in the future: Water
in drinking water quality, avoid long downtimes.
Customer Service
Содержание SB MB
Страница 39: ...Deutsch 39 Ma blatt Variante CAB SB MB Standard SB MB Comfort...
Страница 40: ...40 Deutsch Ma blatt Variante SKID SB MB Standard SB MB Comfort...
Страница 41: ...Deutsch 41 Ma blatt Variante SKID mit Anbausatz WSO...
Страница 80: ...80 English Dimension sheet variant CAB SB MB standard SB MB comfort...
Страница 81: ...English 81 Dimension sheet variant SKID SB MB standard SB MB comfort...
Страница 82: ...82 English Dimension sheet variant SKID with attachment kit WSO...
Страница 123: ...Fran ais 123 Fiche de dimensions variante CAB SB MB Standard SB MB Comfort...
Страница 124: ...124 Fran ais Fiche de dimensions variante SKID SB MB Standard SB MB Comfort...
Страница 125: ...Fran ais 125 Fiche de dimensions variante SKID avec kit de montage WSO...
Страница 165: ...Italiano 165 Scheda dimensionale variante CAB SB MB Standard SB MB Comfort...
Страница 166: ...166 Italiano Scheda dimensionale variante SKID SB MB Standard SB MB Comfort...
Страница 167: ...Italiano 167 Scheda dimensionale variante SKID con kit di fissaggio WSO...
Страница 206: ...206 Nederlands Maatblad variant CAB SB MB standaard SB MB comfort...
Страница 207: ...Nederlands 207 Maatblad variant SKID SB MB standaard SB MB comfort...
Страница 208: ...208 Nederlands Maatblad variant SKID met aanbouwset WSO...
Страница 248: ...248 Espa ol Hoja de medidas variante CAB SB MB Standard SB MB Comfort...
Страница 249: ...Espa ol 249 Hoja de medidas variante SKID SB MB Standard SB MB Comfort...
Страница 250: ...250 Espa ol Hoja de medidas variante SKID con juego de montaje WSO...
Страница 289: ...Svenska 289 M ttblad variant CAB SB MB Standard SB MB Comfort...
Страница 290: ...290 Svenska M ttblad variant SKID SB MB Standard SB MB Comfort...
Страница 291: ...Svenska 291 M ttblad variant SKID med p byggnadssats WSO...
Страница 330: ...330 Suomi Mittalehti versio CAB SB MB Standard SB MB Comfort...
Страница 331: ...Suomi 331 Mittalehti versio SKID SB MB Standard SB MB Comfort...
Страница 332: ...332 Suomi Mittalehti versio SKID liit nt sarjalla WSO...
Страница 337: ...337 2 3 4 2 A 3 3 Powerschaum STOP 1 SB MB Comfort 2 SB MB Comfort 3 SB MB Standard 4 5 6...
Страница 338: ...338 1 2 3 4 5 6 7 8 2 9 1 10 11 12 13 14 1 0 4 0 5 MPa 4 5 bar 1 2 3 4 1 DP 1 2 DP 2 3 DP 3 4 DP 4 1 0...
Страница 350: ...350 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 1 2 48 kW 3 4 24 kW 48 kW 5 6 7 8 1 80 100 m 2 3...
Страница 351: ...351 B C 1 2 3 4 5 6 7 8 9 10 1 11 1 12 13 14 15 16 17 RO 1 2 3 4 5 RO 6 7 RO 8 9 RO 10 11 12 RO 13 14 15...
Страница 352: ...352 1 2 3 1 4 5 1 SB MB 2 Fp 1 2 3 4 5 6 7 2 0 mm 8 9 2 SB MB 2 Fp 1 2 3 4 5 6 7 8 2 0 mm 9 10 11 4 A 4 C D E 1 2...
Страница 353: ...353 1 2 2 3 4 5 6 1 7 8 9 10 11 12 13 2 3 4...
Страница 354: ...354 1 2 2 3 4 5 6 1 7 8 9 10 11 3 2 3 4 1 2 3 4 5 6 7 8 9 10 11...
Страница 355: ...355 SB MB Standard SB MB Comfort RO RO RO RO RO 4 60 C 0 OFF 1 2 K RCHER K RCHER...
Страница 358: ...358 SB MB 6 419 070 0 25 C 0 07 0 15 MPa 0 7 1 5 bar 0 5 l min 0 0 5 l min 2 WZ 30 mm 5 C ABS...
Страница 360: ...360 1000 WSO Power Power WSO RO 5...
Страница 364: ...364 1 2 3 10 C F0144 S5...
Страница 365: ...365 1...
Страница 366: ...366 1 1 2 3 0 6 mm 4 1 3 mm 5 6 7 8 0 25 MPa 2 5 bar WAT S 202 WAT S 202 2...
Страница 367: ...367 0 3 MPa 3 bar RO RO RO RO RO...
Страница 373: ...373 CAB SB MB Standard SB MB Comfort...
Страница 374: ...374 SKID SB MB Standard SB MB Comfort...
Страница 375: ...375 SKID WSO...
Страница 376: ...376...
Страница 380: ...380 1 1 2 2 1 1 1 2 3 4 5 2 3 4 2 3 3 STOP 1 SB MB Comfort 2 SB MB Comfort 3 SB MB Standard 4 5 6 1 2 3 4 5...
Страница 381: ...381 1 2 3 4 5 6 7 8 2 9 1 10 11 12 13 14 1 0 4 0 5 4 5 1 2 3 4 1 DP 1 2 DP 2 3 DP 3 4 DP 4 1 0...
Страница 384: ...384 1 2 1 2 3 4 5 6 7 8 9 10 1 1 2 1 2 3 4 5 6 7 8 9 10 Home 1 2 3 4 5 6 Home 7 1 8 2 2 1 2...
Страница 387: ...387 1 2 3 4 5 6 1 1 2 3 4 5 6 2 3 4 5 6 1 2 3 4 1 2 3 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 20 5 1 2 3 4 5 6 7...
Страница 390: ...390 1 1 2 3 2 3 1 2 3 15 C 4 10 C 4 908 0 C 1 2 15 C 15 C 20 C 20 C 1 K RCHER 1 2 3 C SB MB 200 0 5...
Страница 391: ...391 1 1 1 1 1 1 2 3 2 3 4 1 0 OFF 1 1 ON 2 3 1 2 1 2 3 4 5 6 7 8 9...
Страница 394: ...394 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 1 2 48 3 4 24 48 5 6 7 8 1 80 100 2 3...
Страница 395: ...395 B C 1 2 3 4 5 6 7 8 9 10 1 11 1 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...
Страница 396: ...396 1 2 3 1 4 5 1 SB MB 2 Fp 1 2 3 4 5 6 7 2 0 8 9 2 SB MB SB MB 2 Fp 1 2 3 4 5 6 7 8 2 0 9 10 11 4 A 4 B C D E 1 2...
Страница 397: ...397 1 2 2 3 4 5 6 1 7 8 9 10 11 12 13 2 3 4...
Страница 398: ...398 1 2 2 3 4 5 6 1 7 8 9 10 11 3 2 3 4 1 2 3 4 5 6 7 8 9 10 11...
Страница 399: ...399 SB MB Standard SB MB Comfort 4 60 0 OFF 1 2 K RCHER K RCHER...
Страница 401: ...401 1 2 3 WSO 1 6 1 1 6 2 1 2 1 2 3 1 2 3 4 5 6 1 IP 2 3 4 1 1 2 3 4 1 2 3 4...
Страница 402: ...402 SB MB 6 419 070 0 25 C 0 07 0 15 0 7 1 5 0 5 0 0 5 2 30 5 C...
Страница 403: ...403 40 3 MIN MAX B 6 768 003 3 dH 0 3 0 1 RM 841 10 2 3 RM 841 20 2 3 RM 841 10 2 3 3 C SB MB 1 WSO 80...
Страница 404: ...404 200 9 10 90 100 0 5 5 25 6 288 055 0 6 288 072 6 288 116 1000 WSO WSO...
Страница 408: ...408 10 C F0144...
Страница 409: ...409 1 2 3 S5 1...
Страница 410: ...410 1 1 3 0 6 4 1 3 5 6 7 8 0 25 2 5 WAT S 202 WAT S 202 2...
Страница 411: ...411 0 3 3...
Страница 417: ...417 CAB SB MB Standard SB MB Comfort...
Страница 418: ...418 SKID SB MB Standard SB MB Comfort...
Страница 419: ...419 SKID WSO...
Страница 420: ...420...
Страница 422: ......
Страница 423: ......