background image

R E A D   T H I S   M A N U A L

This manual contains important information for the use and safe operation of 
your RAMTEQ

®

 machine.  FAILURE TO READ THIS MANUAL AND 

FOLLOW ITS INSTRUCTIONS PRIOR TO OPERATING OR ATTEMPTING 
ANY  SERVICE  OR  MAINTENANCE  PROCEDURE  COULD  RESULT  IN 
SERIOUS INJURY OR DEATH TO YOU OR OTHER PERSONS; ALSO
DAMAGE TO THE MACHINE OR TO OTHER PROPERTY.

O

perator

s

 M

anual

BVE SERIES

 Electric Motor / Diesel fired

RAMTEQ

®

  

14275  northwest  freeway     

    houston,  tX    77040     

   phone:  713.983.6000     

    faX:  713.983.6405

   

  

300-00002-01 11/05

Содержание BVE Series

Страница 1: ...OW ITS INSTRUCTIONS PRIOR TO OPERATING OR ATTEMPTING ANY SERVICE OR MAINTENANCE PROCEDURE COULD RESULT IN SERIOUS INJURY OR DEATH TO YOU OR OTHER PERSONS ALSO DAMAGE TO THE MACHINE OR TO OTHER PROPERT...

Страница 2: ...BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN This operator s manual contains information protected by copyright No part of this operator s manual may be photocopied or rep...

Страница 3: ...riods of time with trigger gun closed Damage to pump may occur DO NOT operate this machine in an unsafe manner or around unsupervised children Keep all other personnel clear while operating this machi...

Страница 4: ...or float tank if equipped Turn on water source Connect the power cord to a properly grounded power source Attach high pressure hose to base of spray gun Install water nozzle at the end of wand making...

Страница 5: ...efficiency of the coil FAILURE TO MAINTAIN HEAT EXCHANGER COIL MAY RESULT IN A STEAM EXPLOSION WHICH MAY CAUSE SERIOUS INJURY OR DEATH WARNING Maintenance Instructions MOVING STORAGE Place machine in...

Страница 6: ...lack smoke is first noticed Slowly open air band until white smoke vents then turn air band halfway back to where black smoke was first noted Tighten air band locking screw When properly set the unit...

Страница 7: ...009 01 Handle 1 180 00038 01 Wand Box 1 567 00015 01 Grommet Rubber Wand Holder 2 1 12 180 00020 01 Shell SS Removable 18 X 23 H 1 191 00006 01 Insulation Blanket 1 x 24 w 4 1 13 180 00072 01 Cap Coil...

Страница 8: ...0028 04 Nozzle Water 5 5 40 BVE 1000 1 2 265 00001 01 36 Wand Insulated 1 3 275 00001 01 ST1500 Trigger Gun 1 4 552 00004 03 3 8 Quick Connect Female Plug 1 5 284 00001 01 Hose 3 8 X 50 R 1 Swivel End...

Страница 9: ...ssemblies 9 8 1 2 4 3 7 6 Ref Part Description Qty 1 251 00001 01 Fuel Pump w Solenoid 115v 1 2 256 00001 02 Main Burner Gasket 1 3 245 00012 16 Nozzle 1 4 258 00002 02 Electrode Pair 1 pr 5 252 00001...

Страница 10: ...05 BV500 06 BV500 04 MODELS THERMOSTAT MANIFOLD FROM COIL OUTLET 1 2 NPT X 2 5 NIPPLE GALVANIZED STEEL JE ADAMS 7420 2500 PSI RELIEF VALVE 3 8 NPTM X 3 8 MALE QUICK CONNECT COUPLER BUSHING PLATED STEE...

Страница 11: ...M X 3 8 MALE 528 00006 01 ELBOW PLATED STEEL 3 8 NPT STREET 5833 PSI RUPTURE DISK QUICK CONNECT COUPLER NIPPLE GALVANIZED STEEL 1 2 I D X 51 LOW PRESSURE HOSE MANIFOLD 1 2 NPT X 2 5 BV1000s FROM COIL...

Страница 12: ...ransformer Orange Fuel for Ignitor Red Solenoid Wht Burner Mtr Blk BLK F3 WHT BLUE Motor Pump WHT WHT T2 T1 T3 BLK ORANGE F1 F2 T1 BLUE WHT BLK WHT BLK ORANGE RED WHT WHT 96 95 M1 RED OL OL OL M1 L1 L...

Страница 13: ...RMETER d e R e g n a r O Blk Solenoid Fuel Burner Motor Wht Transformer for Ignitor Blk Wht BLK Wht F3 WHT BLUE Motor Pump WHT T2 T1 T3 BLK ORANGE F1 F2 T1 WHT BLK RED WHT WHT 96 95 M1 RED OL OL OL M1...

Страница 14: ...former Mtr Fuel Solenoid BLK WHT ORANGE BLUE WHT BLK F3 BLUE BLK WHT WHT F2 T1 F1 T2 OL OL T1 96 OL T3 M1 WHT L1 95 WHT BLK M1 L3 RED BLK WHT ORANGE BLK RED H4 H2 H3 H1 X1 X2 L2 L1 208 230V ELEC BOX L...

Страница 15: ...otection OL WHT BLUE ORANGE BLK WHT F2 BLK RED F1 BLK WHT WHT 95 96 RED Blue Red Wht Blk Orange Blk BLK Orange Red Wht Blk for Ignitor Transformer Wht Mtr Burner Fuel Solenoid PUMP SW HOURMETER Red Bl...

Страница 16: ...Wht Blk Fuel Solenoid for Ignitor Transformer Wht Mtr Burner PUMP SW T2 WHT WHT WHT WHT T1 F1 F3 BLK F2 BLK protection overload w thermal Contactor Motor M1 RED OL OL OL T3 M1 WHT BLK L1 L3 96 95 RED...

Страница 17: ...ormer Wht Mtr Burner Wht Blk HOURMETER Wht BURNER MODULE CONTROL PANEL Red PUMP SW T2 WHT WHT WHT WHT T1 F1 F3 BLK F2 BLK protection overload w thermal Contactor Motor M1 RED OL OL OL T3 M1 WHT BLK L1...

Страница 18: ...to specifications Dirty burner nozzle Clean or replace burner nozzle Pressure Relief Valve Leaks Nozzle is dirty Clean or replace nozzle Defective relief valve Replace relief valve Unloader adjusted i...

Страница 19: ...eration outside the specifications in the intended applications c by the use of parts not sold or manufactured by RAMTEQ d by the modification of the Product Warranty Disclaimer EXCEPT AS EXPRESSLY SE...

Страница 20: ...75 NORTHWEST FREEWAY HOUSTON TX 77040 PHONE 713 983 6000 FAX 713 983 6405 1 13 Click on pictures to open manufacturers website Manufacturers Warranty Period 5 years 5 years 3 years 3 years 3 years 18...