p

age

 

MAInTEnAncE PREcAuTIOns

   

Do not permit acidic, caustic or abrasive fluids to be pumped through system.

   

Periodically clean detergent inlet screen. This will ensure proper flow of water to the pump.

   

High mineral content in water may adversely affect your machine and may require the use of a water softener

      to ensure proper operation.

   NEVER run the pump dry under any circumtances. Doing so will cause exteme damage to the pump.

hEAT EXchAnGER cOIl MAInTEnAncE

 

 

Hard water conditions may eventually cause clogging in the heat exchanger coil if  left unattended.  

      Scale deposits will compromise the heating efficiency and produce an unsafe condition over time.  

      It may be necessary to descale coil.

      

   

Scale buildup from certain detergents may eventually clog up the heat exchanger coil causing an 

      unsafe condition. Use only recommended detergents for better cleaning efficiency.  

   

Black carbon deposits that collect on the outside wall of the heat exchanger coil may be a result of 

      using a poor grade of fuel or improper burner operation.  Heating fuel should be void of water and 

      sediments to eliminate the possibility of sooting and compromising the efficiency of the coil. 

FAIluRE TO MAInTAIn hEAT EXchAnGER cOIl MAy 

REsulT In A sTEAM EXPlOsIOn WhIch MAy cAusE 

sERIOus InjuRy OR dEATh.

WARNING

Maintenance Instructions

MOvInG, sTORAGE

 

   

Place machine in covered area when not in use to protect from elements.Protect machine from

       freezing in cold temperatures by storing in a heated location.

WInTERIZInG

   

Non-float Tank Machines: To protect the machine from freezing temperatures while 

      storing or transporting, connect short length of garden hose (approximately 3 ft.) to 

      water inlet connection on machine. Remove the pressure nozzle from the wand and

      insert the short garden hose end into a container of antifreeze. Place the wand into the 

      antifreeze container and start engine running machine until antifreeze appears from the

      end of the wand. Turn engine “OFF” and replace pressure nozzle.  Coil up hose and 

      move machine to storage area.

   

Float Tank Machines: Pour antifreeze into float tank and remove water nozzle from end

      of wand and carefully insert into opening of float tank.  Start machine and run until 

      antifreeze water mixture has circulated throughout the machine returning back to the

      float tank.

PuMP MAInTEnAncE

   

Fill crankcase to dot on oil gauge window per specifications with the specific oil created by the pump 

       manufacturer (i.e. 

General Pump Oil

). Ensure the right oil for specific pump as it may vary.

   

Change oil after 

40 Hour Break-in Period.

   

Change oil every 

Three Months or at 500 Hour Intervals 

thereafter.

Содержание BVE Series

Страница 1: ...OW ITS INSTRUCTIONS PRIOR TO OPERATING OR ATTEMPTING ANY SERVICE OR MAINTENANCE PROCEDURE COULD RESULT IN SERIOUS INJURY OR DEATH TO YOU OR OTHER PERSONS ALSO DAMAGE TO THE MACHINE OR TO OTHER PROPERT...

Страница 2: ...BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN This operator s manual contains information protected by copyright No part of this operator s manual may be photocopied or rep...

Страница 3: ...riods of time with trigger gun closed Damage to pump may occur DO NOT operate this machine in an unsafe manner or around unsupervised children Keep all other personnel clear while operating this machi...

Страница 4: ...or float tank if equipped Turn on water source Connect the power cord to a properly grounded power source Attach high pressure hose to base of spray gun Install water nozzle at the end of wand making...

Страница 5: ...efficiency of the coil FAILURE TO MAINTAIN HEAT EXCHANGER COIL MAY RESULT IN A STEAM EXPLOSION WHICH MAY CAUSE SERIOUS INJURY OR DEATH WARNING Maintenance Instructions MOVING STORAGE Place machine in...

Страница 6: ...lack smoke is first noticed Slowly open air band until white smoke vents then turn air band halfway back to where black smoke was first noted Tighten air band locking screw When properly set the unit...

Страница 7: ...009 01 Handle 1 180 00038 01 Wand Box 1 567 00015 01 Grommet Rubber Wand Holder 2 1 12 180 00020 01 Shell SS Removable 18 X 23 H 1 191 00006 01 Insulation Blanket 1 x 24 w 4 1 13 180 00072 01 Cap Coil...

Страница 8: ...0028 04 Nozzle Water 5 5 40 BVE 1000 1 2 265 00001 01 36 Wand Insulated 1 3 275 00001 01 ST1500 Trigger Gun 1 4 552 00004 03 3 8 Quick Connect Female Plug 1 5 284 00001 01 Hose 3 8 X 50 R 1 Swivel End...

Страница 9: ...ssemblies 9 8 1 2 4 3 7 6 Ref Part Description Qty 1 251 00001 01 Fuel Pump w Solenoid 115v 1 2 256 00001 02 Main Burner Gasket 1 3 245 00012 16 Nozzle 1 4 258 00002 02 Electrode Pair 1 pr 5 252 00001...

Страница 10: ...05 BV500 06 BV500 04 MODELS THERMOSTAT MANIFOLD FROM COIL OUTLET 1 2 NPT X 2 5 NIPPLE GALVANIZED STEEL JE ADAMS 7420 2500 PSI RELIEF VALVE 3 8 NPTM X 3 8 MALE QUICK CONNECT COUPLER BUSHING PLATED STEE...

Страница 11: ...M X 3 8 MALE 528 00006 01 ELBOW PLATED STEEL 3 8 NPT STREET 5833 PSI RUPTURE DISK QUICK CONNECT COUPLER NIPPLE GALVANIZED STEEL 1 2 I D X 51 LOW PRESSURE HOSE MANIFOLD 1 2 NPT X 2 5 BV1000s FROM COIL...

Страница 12: ...ransformer Orange Fuel for Ignitor Red Solenoid Wht Burner Mtr Blk BLK F3 WHT BLUE Motor Pump WHT WHT T2 T1 T3 BLK ORANGE F1 F2 T1 BLUE WHT BLK WHT BLK ORANGE RED WHT WHT 96 95 M1 RED OL OL OL M1 L1 L...

Страница 13: ...RMETER d e R e g n a r O Blk Solenoid Fuel Burner Motor Wht Transformer for Ignitor Blk Wht BLK Wht F3 WHT BLUE Motor Pump WHT T2 T1 T3 BLK ORANGE F1 F2 T1 WHT BLK RED WHT WHT 96 95 M1 RED OL OL OL M1...

Страница 14: ...former Mtr Fuel Solenoid BLK WHT ORANGE BLUE WHT BLK F3 BLUE BLK WHT WHT F2 T1 F1 T2 OL OL T1 96 OL T3 M1 WHT L1 95 WHT BLK M1 L3 RED BLK WHT ORANGE BLK RED H4 H2 H3 H1 X1 X2 L2 L1 208 230V ELEC BOX L...

Страница 15: ...otection OL WHT BLUE ORANGE BLK WHT F2 BLK RED F1 BLK WHT WHT 95 96 RED Blue Red Wht Blk Orange Blk BLK Orange Red Wht Blk for Ignitor Transformer Wht Mtr Burner Fuel Solenoid PUMP SW HOURMETER Red Bl...

Страница 16: ...Wht Blk Fuel Solenoid for Ignitor Transformer Wht Mtr Burner PUMP SW T2 WHT WHT WHT WHT T1 F1 F3 BLK F2 BLK protection overload w thermal Contactor Motor M1 RED OL OL OL T3 M1 WHT BLK L1 L3 96 95 RED...

Страница 17: ...ormer Wht Mtr Burner Wht Blk HOURMETER Wht BURNER MODULE CONTROL PANEL Red PUMP SW T2 WHT WHT WHT WHT T1 F1 F3 BLK F2 BLK protection overload w thermal Contactor Motor M1 RED OL OL OL T3 M1 WHT BLK L1...

Страница 18: ...to specifications Dirty burner nozzle Clean or replace burner nozzle Pressure Relief Valve Leaks Nozzle is dirty Clean or replace nozzle Defective relief valve Replace relief valve Unloader adjusted i...