Low water Pressure
Insufficient water source
Check hose size/water source
Old or incorrect nozzle
Replace nozzle
Plumbing or hose leak
Tighten, repair or replace leak
Obstruction in spray nozzle
Clean or replace nozzle
Chemical valve open
Close valve or submerge hose
Unloader valve worn
Replace unloader
Pump valves dirty or worn
Clean or replace packing/valves
No Chemical Flow
Detergent valve closed
Open detergent valve
Low detergent level
Fill detergent container
Chemical screen dirty
Clean detergent screen
Burner Not Igniting
No fuel
Fill fuel tank with proper fuel
Burner switch turned off
Turn burner switch on
Thermostat set too low
Reset thermostat
Clogged fuel filter
Replace fuel filter
Defective pressure switch
Replace pressure switch
Clogged burner nozzle
Replace burner nozzle
Fuel pump malfunction
Replace fuel pump
Improper electrode setting
Clean/reset to specifications
Excessive Burner Smoke
Improper fuel being used
Use Diesel #1/#2 or Kerosene
water contamination in fuel
Drain fuel and replace with new
Improper air band adjustment
Readjust air band/altitude
Low fuel pressure
Adjust to specifications
Air leaks in fuel lines
Check for air leaks or bubbles
Soot on coils/burner assembly
Clean coils/burner assembly
Misaligned electrodes
Realign to specifications
Dirty burner nozzle
Clean or replace burner nozzle
Pressure Relief Valve Leaks
Nozzle is dirty
Clean or replace nozzle
Defective relief valve
Replace relief valve
Unloader adjusted incorrectly
Adjust unloader valve
Restriction on discharge hose
Remove nozzle and flush line
Scale restricting flow in coil
Clean coil
Pump Motor Not Running
Pump motor switch off
Turn on pump motor switch
GFCI tripped
Reset and test GFCI
No voltage to machine
Check power source
Clogged water nozzle
Clean water nozzle
Insufficient voltage/amperage
Use proper drop cord
Pump Noisy
Air in suction line
Check inlet water fittings
Pump valves dirty
Clean/replace pump valves
Check valve springs worn
Replace check valves
Low pump oil
Add SEA 30wt. non-detergent
Pump bearings are worn
Replace/rebuild pump
Incoming water too hot
Reduce temperature/ambient
water In Oil
High humidity environment
Change oil frequently
Oil seal worn
Check and replace oil seal
Plunger packing worn
Check and replace packing
water Dripping/Pump
Plunger packing is worn
Install new packing kit
Plunger retainer oil ring worn
Replace oil ring
Cracked ceramics
Replace ceramics
Oil Dripping
Oil seal worn
Check and replace oil seals
Cracked manifold
Replace manifold
Fluctuating Pressure
Unloader not adjusted
Adjust to specifications
Valves worn
Replace with valve kit
Dirt or blockage in valves
Clean or replace valve
Pump sucking air
Check water/detergent supply
worn plunger packing
Replace packing kit
Pump Head Overheating
Extended period in bypass
Pull trigger gun for water flow
problem
cause
action
troubleshooting