Operation
7.0.2
Check spin
It is good practice to perform a check spin after applying
the weights.
•
Spin the wheel.
Having fi nished the Test Run, if the wheel is balanced
correctly, both the numerical indicators should indicate
0
and an
OK
should be displayed (
Fig. 7-10
).
Note
If there is no OK reading, dynamic unbalances below
the tolerance limit add to a static unbalance above the
tolerance limit.
To check how much imbalance is left:
•
Select the FINE key, (
21,Fig. 7-10
).
Note
:
The operator should decide if applying the
stated weight is necessary.
7.0.3
Results recalculation
After spinning a wheel it is possible to enter new rim
data or select another weight mode. The results are
recalculated automatically, if possible.
Selecting another weight mode
•
Between NORMAL, ALU and STATIC: no additional
steps required.
To have a recalculation done:
•
Select the prefered Weight Mode. Check and/or
edit rim or plane data when necessary.
•
Rotate the wheel to the left plane WAP position and
apply the weight.
•
Rotate the wheel to the right plane WAP position
and apply the weight.
•
Perform a check spin.
..